Abbott Cell Dyn Ruby - 5 Part Differential Hematology Analyzer

Abbott Cell Dyn Ruby - 5 Part Differential Hematology Analyzer

Contact us for price

Description

The Abbott Cell-Dyn Ruby Hematology System 


For reliable performance that leads to quality results—the first time—CELL-DYN Ruby delivers and outperforms similar tools. With advanced capabilities for the medium-sized laboratory, you can process more in less time.


Includes:

·         Abbott Cell-Dyn Ruby

·         Pickup tubes

·         Sample Racks

·         Touch Monitor

·         Software

·         All connections

Features:

·         84 tests/hour maximum throughput

·         CBC + 5-part differential

·         Reticulocyte testing

·         4-angle optical WBC differential technology

·         Dual-angle optical platelet analysis

·         Only 4 reagents required

·         10,000-result onboard storage

·         Integrated QC and statistical tools

·         Levey-Jennings and Westgard QC

·         Rules-based result annotations

·         Color touchscreen interface

·         Automated calibration, reagent, and maintenance monitoring

·         Designed for efficient, high-volume laboratory operation


Specifications:

  • Maximum Throughput: Up to 84 CBC + Differential tests/hour in Autoloader Mode
  • Sample Volume:Open Mode: 150 µL
  • Sample Loader: 230 µL
  • Reagents: Only 4 reagents, including reticulocyte reagent
  • Sample Type: Whole blood
  • System Control Center: Single computer with color touch-screen monitor, keyboard, and mouse

Measurement Ranges

  • WBC: 0.02–246.8 × 10³/µL
  • RBC: 0.00–7.50 × 10⁶/µL
  • HGB: 0.0–25.0 g/dL
  • HCT: 8.3–79.8%
  • MCV: 58–139 fL
  • RDW: 10.0–29.8%
  • PLT: 0.0–3000 × 10³/µL
  • MPV: 4.3–17.2 fL
  • RETC: 0.2–22.9%

Physical Specifications

  • Height: 19.25 in (49.9 cm)
  • Width: 34 in (86.4 cm)
  • Depth: 30.25 in (76.8 cm)
  • Weight: 232 lb (105.2 kg)

Electrical Specifications

  • Voltage: 100–240 VAC
  • Frequency: 50/60 Hz
  • Maximum Power Consumption: 550 W
  • Power Specifications: Analyzer only

Reagents

  • WBC Lyse: 3.8 L Cubitainer
  • Diluent / Sheath: 20 L Cubitainer
  • CN-Free HGB / NOC Lyse: 3.8 L Cubitainer
  • Reticulocyte Reagent: 5.0 mL tubes, each containing 3.7 mL reagent


International Diagnostic Equipment 

- Call or email with your questions, Hablamos Español

- Ship from: IDE - Southern California. Global Shipping

- Details of item must be read carefully before buying and /or requesting return

 

Disclaimer:


"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item."

Specifications

ManufacturerAbbott
ModelRuby
ConditionRefurbished
Stock Number6
Maximum Throughput (Autoloader Mode)CBC + Differential: Up to 84 per hour
Sample VolumeOpen Mode 150 μL, Sample Loader 230 μL
ReagentsOnly 4 reagents including reticulocytes
PlateletsDual angle optical analysis, no extra reagent, no reflex testing requirement
ReticulocytesNew Methylene Blue NCCLS method, supravital staining technique
RBC0.00–7.50 x 106/μL
HGB0.0–25.0 g/dL
HCT8.3-79.8%
MCV58–139 fL
RDW10.0-29.8%
PLT0.0–3000 x 103/μL
MPV4.3-17.2 fL
RETC0.2–22.9%
Data ManagementWindows®-based operating system. Rules-based result annotations. Full on-board QC package. Levey-Jennings plots. Moving Averages. Westgard rules. 10,000 results stored with graphics. Auto calibration online guide.
System Control CenterA single computer with color touch-screen monitor, keyboard, and mouse
Dimensions (HxWxD)Height – 19.25 inches (49.9 cm) Width – 34 inches (86.4 cm) Depth – 30.25 inches (76.8 cm)
Weight232 pounds (105.2 kilograms)
Electrical Requirements*VAC 100-240V, 50/60Hz
Maximum Power Consumption*550 watts
REAGENT DESCRIPTIONSSIZE AND LIST NUMBER
WBC Lyse3.8 L cubitainer (08H52-01)
Diluent / Sheath20 L cubitainer (01H73-01)
CN free HGB / NOC Lyse3.8 L cubitainer (03H80-02)
Reticulocyte5.0 mL tubes, each tube containing 3.7 mL of reagent (03H40-01)
CONTROL/CALIBRATORSTABILITY
CELL-DYN 26 Plus ControlOpen Vial: 8 days
CELL-DYN Retic Plus ControlOpen Vial: 14 days
CELL-DYN 29 Plus Control (With Retic)Open Vial: 7 days
CELL-DYN HemCal Plus CalibratorOpen Vial: 5 days