Roche Cobas E411 Immunoassay Analyzer
Includes:
One cobas E411 analyzer with computer, software, bench, and manual.
Features:
The cobas e 411 analyzer is a fully automated analyzer that uses a patented ElectroChemiLuminescence (ECL) technology for immunoassay analysis. It is designed for both quantitative and qualitative in vitro assay determinations for a broad range of applications (including anemia; bone, cardiac and tumor markers; critical care; fertility/hormones; and infectious diseases). The analyzer is available as a rack or disk sample handling system.
Features/Benefits
Test Menu
Elecsys® ACTH | Elecsys® Anti-TPO | Elecsys® Cyclosporine | Elecsys HBeAg |
Elecsys® AFP | Elecsys® Anti-TSHR | Elecsys® CYFRA 21-1 | Elecsy HBsAg Confirmatory Test |
Elecsys® AMH | Elecsys® C-Peptide | Elecsys® DHEA-S | Elecsys HBsAg II |
Elecsys® Anti-CCP | Elecsys® CA 125 II | Elecsys® Digoxin | Elecsys CG STAT |
Elecsys® Anti-HAV | Elecsys® CA 15-3 II | Elecsys® Estradiol III | Elecsys CG+ |
Elecsys® Anti-HAV IgM | Elecsys® CA 19-9 | Elecsys® Ferritin | Elecsys HE4 |
Elecsys® Anti-HBc IgM | Elecsys® Calcitonin | Elecsys® Folate III | Elecsys hGH |
Elecsys® Anti-HBc II | Elecsys® CEA | Elecsys® Folate RBC | Elecsys HSV-1 IgG |
Elecsys® Anti-HBe | Elecsys® CK-MB | Elecsys® free PSA | Elecsys HSV-2 IgG |
Elecsys® Anti-HCV II | Elecsys® CMV IgG | Elecsys® free βhCG | Elecsys IgE II |
Elecsys® Anti-SARS-CoV-2 S | Elecsys® CMV IgM | Elecsys® FSH | Elecsys IGF-1 |
Elecsys® Anti-Tg | Elecsys® Cortisol II | Elecsys® FT3 III | Elecsys IGFBP-3 |
Elecsys® IL-6 | Elecsys Prolactin II | Elecsys® Tacrolimus | |
Elecsys® Insulin | Elecsys PTH | Elecsys® Testosterone II | |
Elecsys® LH | Elecsys Rubella IgG | Elecsys® total PSA | |
Elecsys® Myoglobin | Elecsys Rubella IgM | Elecsys® Total-Tau CSF | |
Elecsys® N-MID Osteocalcin | Elecsys S100 | Elecsys® Toxo IgG | |
Elecsys® NSE | Elecsys SARS-CoV-2 Antigen | Elecsys® Toxo IgM | |
Elecsys® PAPP-A | Elecsys sFlt-1 | Elecsys® Troponin I | |
Elecsys® Phospho-Tau (181P) CSF | Elecsys SHBG | Elecsys® TSH | |
Elecsys® PlGF | Elecsys Syphilis | Elecsys® Vitamin B12 II | |
Elecsys® proBNP II | Elecsys T-Uptake | Elecsys® Vitamin D total II | |
Elecsys® Progesterone III | Elecsys T3 | Elecsys® β-CrossLaps/serum | |
Elecsys® ProGRP | Elecsys T4 |
Specifications
Manufacturer | Roche Diagnostics |
Condition | New |
Weight | Disk: 180 kg / 397 lbs Rack: 250 kg / 551 lbs |
System | Fully automated, immunoassay analyzer for random access processing of ECL-based immunoassays (cobas e system format) |
System components | Self contained bench top analyzer comprising an analytical unit and a customized user interface |
Types of modules | cobas e 411 disk analyzer cobas e 411 rack analyzer Optional System Table (cabinet); Optional System Table Extension (for printer) |
System interfaces | RS232 serial interface, bidirectional |
Throughput | Up to 86 tests/hour |
Number of reagent channels | 25 reagent slots with a maximum of 18 on-board assays |
Programmable test parameters | N/A, programming-by-loading (PBT) concept, application data are transferred without operator intervention from the 2D barcode of the reagent pack (RP) into the instrument database |
Sample materials | Serum/plasma, urine, others |
Sample input/output | 30 positions for samples, calibrators and controls 15 racks with 5 samples each (= 75 samples in/out) |
Sample volume | 10 – 50 μl. |
Sample clot detection | Standard (pressure sensor) |
Sample barcode types | Code 128; Codabar (NW 7); Interleaved 2 of 5; Code 39 |
Control unit | Microsoft® Windows® XP-based panel PC |
Calibrator/QC input | cobas e system-specific barcoded CalSet vials on disk or racks |
Calibration methods | Lot calibration (L-cal); Reagent Pack (RP) calibration (R-Cal) |
QC methods | Individual QC and cumulative QC Up to 100 controls pre-programmable |
Data storage capacity | The memory contains data files necessary for the analyzer and software to work together: Reagent Data File: Up to 300 reagent packs Sample Data File: Up to 2000 test records (for samples and controls) Calibration Data File: Up to 160 calibrators – QC Data File: Capacity up to 100 controls Operating Parameter Data File: Up to 305 reagent applications Up to 20 operator IDs |
Electrical requirements | 230/110 Volts AC; 1,000 kVA (disk), 1,250 kVA (rack) Frequency: 50 Hz or 60 Hz +/- 0.5% |
Water/Waste requirements | Water: Bacteria free, de-ionized water supply, resistance of less than 10 μS/cm Liquid waste: Onboard waste container (4 liter), direct drain optional |
Operating conditions | Ambient temperature: 18 to 32°C Ambient humidity: 20 to 80% RH (without condensation) Heat Output: 2,879 kJ/hr (analyzer unit) Noise Output: 60 dBA (stand-by), 63 dBA (operation avg.) |
Physical dimensions | Width (disk/rack): 120 cm / 170 cm 47.2 in / 67 in Depth (disk/rack): 73 cm / 95 cm 28.7 in / 37.4 in Height: 80 cm / 31.4 in (closed top cover) 109 cm / 43 in (opened top cover) |