Randox RX Imola Chemistry/Toxicology Analyzer

Randox RX Imola Chemistry/Toxicology Analyzer

Contact us for price

Description

Includes:

One Randox RX Imola Analyzer.

Providing excellence in clinical chemistry, the RX imola fully automated system combines robust hardware and intuitive software with a wide range of unique and innovative features.

Features/Benefits

Features:

The RX imola comprises the RX series world leading test menu covering routine chemistries, specific proteins, lipids, therapeutic drugs, antioxidants, diabetes and veterinary testing. Leading the way, the RX imola has testing capabilities for a wide range of our high performing and unique assays including Direct HbA1c. Capable of analyzing a variety of sample types including Serum, Plasma and Urine.

 

Providing excellence in clinical chemistry, the RX imola fully automated system combines robust hardware and intuitive software with a wide range of unique and innovative features.

 

-Liquid level sensor, crash, bubble and clot detection

-Low water consumption of just 18 litres per hour

-Versatile reagent carousel with 60 cooled positions

-Unique loading hatch allows emergency samples to be analyzed quickly and easily at any time

-90 permanent Pyrex® cuvettes with innovative cuvette check functionality which optimizes analyzer performance

-Universal sample carousel with 72 positions and 20 cooled control and calibrator positions

-Dual 5 speed stirrers enabling mixing to be optimized for each assays requirements

-Sleep and auto start functionality and automatic re-runs of sample for faults detected

-Maximum of 5 minutes daily maintenance required

 

Specifications: PHYSICAL DIMENSIONS PERFORMANCE CHARACTERISTICS REAGENT & SAMPLE SYSTEM REACTION SYSTEM CALIBRATION & QC POWER & CONNECTIVITY OPERATING SYSTEM

Specifications

ConditionNew
Height690 mm, 27in
Depth582 mm, 23in
Width970 mm, 38in
Weight150 kg, 331lbs
Throughput400 photometric tests per hour, 240 ISE tests per hour. Combined throughput of 560 tests per hour
Analyzer accreditationCE marking in compliance with In Vitro Diagnostic Medical Device Directive 98/79/EC, FDA 510k cleared and UL certification
Analyzer typeCompact fully automated random access bench top clinical analyzer
Assay testsEndpoint, kinetic, biochromatic, turbidmetric, sample blanking, reagent blanking and ISE
MaintenanceDaily maintenance-less than 5 minutes. No rear access required. Simple twice yearly preventative maintenance service
Data managementStorage of up to 30,000 patient reports, search facility, test counter
Test channels60 photometric channels, 3 direct ISE tests – sodium, potassium and chloride
Sleep modeUser defined sleep mode capabilities with automatic wash and instrument prep
Reagent capacityRemovable tray with 60 cooled positions (30 positions for 100 or 50ml bottles and 30 positions for 20ml bottles)
Reagent cooling8-15°C
Reagent identificationAutomatic barcode reagent identification
Reagent inventoryCalculation of remaining reagent volume and tests available, alert for shortage, expired reagent and expired calibration
Reagent pipetteDedicated twin reagent micropipette with liquid level sensor and crash detection, rinsed inside and outside with purified water
Sample additionImmediate sampling interruption for addition of samples via removable panel
Sample capacityRemovable tray with 72 positions for samples, 20 cooled position for controls and calibrators
Sample dead volume150µl in standard or primary tubes, 100µl in paediatric cups
Sample dilutionPre-dilution and automatic re-assay with diluted, reduced or increased sample volume. Dilution mixture 100 -350µl consisting of 2-35µl of sample and 20-350µl of diluent
Sample identificationBarcode sample identification
Sample pipetteDedicated sample micropipette with liquid level sensor, crash detection, bubble detection and 4 levels of clot detection. Rinsed inside and outside with purified water
Sample tube SizeMultiple primary tube sizes (diameter 13 to 16mm, height 75 to 100 mm), pediatric cups
Sample typeSerum, Plasma, Urine, Supernatant & Whole Blood
Sample volume2 to 35µl (0.1µl increments)
STAT samplingImmediate STAT sampling interruption
Minimum reaction volume150µl
Stirring speedDual 5-speed rotating stirrers rinsed with purified water
Stirring systemPaddle type rotating stirrer cleaned with purified water
Temperature37°C±0.3
Cuvettes90 reusable Pyrex® cuvettes with 5-year lifespan, min volume 150µl, Max volume 450µl, 8-stage cuvette washing system
Cuvette size8(W) x 6.23(D) x 30(H) mm
Cycle time9 seconds
Water consumption18L per hour
Water requirementsNCCLS type 1 or 2 purified water supply at pressure [0.15-0.34Mpa]
Detector methodDirect absorbance in cuvette (bichromatic and monochromatic)
Detection principal12 wavelengths: 340, 380, 415, 450, 510, 546, 570, 600, 660, 700, 750 and 800 nm
ISE testsIntegrated ISE unit
Light sourceHalogen tungsten lamp (air-cooled, 6 months service life)
Quality controlInteractive Levey-Jennings Charts, Daily, Monthly and Batch QC with data archiving, Automatic QC and Automatic calibration
Calibration principalFactor, Linear, point to point, spline, log-logit and exponential. Up to 7 calibrators per test
Input voltage100 – 240 Vac
Power consumption<900VA
UPS Requirements1230 W (Analyzer and PC)
LIMS ConnectivityBi-Directional; ASTM standard (RS232 Connection)
Operator interface15” LCD display and printer externally connected. Windows based user interface