Roche Cobas 6000 (c501 + e601) Chemistry Analyzer

Roche Cobas 6000 (c501 + e601) Chemistry Analyzer
Contact us for price
Description
Roche Cobas 6000 (C501 + E601) Chemistry Analyzer for sale
The Cobas 6000 analyzer series offer tailor-made solutions to medium to large workload laboratories. Flexible combinations of clinical chemistry (cobas c 501 module) and immunochemistry testing (cobas e 601 module) modules are available.
CORE UNIT :
Single control unit for all modules
COBAS C501 MODULE
Clinical chemistry, homogeneous immunoassays, ISE, HbA1c (whole blood measurement).
Automated rerun and dilution
COBAS E601 MODULE
Heterogeneous immunoassays including cardiac markers, anemia, bone and tumor markers, hormones, and infectious diseases.
Automated rerun and dilution
Escape from corporate service contracts in California
The quality of service contracts from manufacturers has declined over the last 10 years.
They’re less responsive. Slower. More corporatized. You submit service tickets or contact your service tech through a central email inbox.
Most lab managers aren’t interested in all that hooplah. You want an easy transaction to get your system up and running again.
Your service agreement with us is more like this:Your refurbished Roche Cobas 6000 or other Roche Cobas system is returned to like-new specs – like the day it rolled off the Hitachi production line.
But it’s tens of thousands of dollars less than the day it rolled off that production line.
The capacity it adds to your lab means the investment pays for itself within 2 years.
And the responsive service you get from us means your uptime is better than your other analyzers (unless you lump all your service together with us – then your entire lab’s uptime will increase by weeks annually).
Even large labs have to manage expenses carefully. They have to be profitable.
You can get financing terms quickly with us. Then the increase in efficiency, reduced overall testing downtime, and increased test throughput (coupled with the low purchase price of a refurbished Roche Cobas) account for most of your payments.
The improvements in your lab pay for themselves.
Finance your Roche Cobas & let it pay for itself Manage your capital equipment budget easilyYour refurbished Roche Cobas is returned to OEM-or-better condition (because over the last 15 years, replacement parts have improved in quality).
You reduce the wear and tear on your primary analyzers. You reduce the cost of repairs.
You may extend the lifespan of your more expensive chemistry analyzers by 5+ years.
Click here & make your job easierMake onboarding new staff easier in California
Hiring new staff in your lab is challenging.
Labs managers are bending over backwards to retain their experienced staff.
They’re the most valuable asset in any lab because experienced operators can step into any scenario and adapt quickly. They can handle the steep learning curves of new equipment and processes.
The pool of experienced operators who are going to move from their job to a new role in your lab is small. You usually have a large pool of less experienced lab technicians to choose from, and the time you put into that inexperienced candidate is risky.Because it’s been in circulation for more than 15 years, there’s a good chance that most inexperienced candidates have still used it. They’re likely even proficient using it.
Your training time is drastically reduced.
Their rate of errors is drastically reduced.
The oversight you have to give them in the first 9 months is drastically reduced.
It’s a bit like a babysitter for baby lab techs. But you don’t have to buy it pizza. Click here for a quick quote Get personal, responsive service in California that values your time “Roche doesn’t have the service techs in my region any more to support our Cobas 6000 workhorse. So we almost had to retire the system that churns out our most common tests. But we found IDE and started working with a service engineer who lives 10 minutes away. We have more uptime now and we’re considering adding a refurbished system to help cope with the growing expectations to generate results faster than ever.” So. Cal. Medical CenterHow many times have you had to convince your service provider you need them
How often have they patronized you? Frustrated you? Treated you like you’re doing something wrong?
When you call or text your service engineer at IDE directly, you get help from a friend. We’re a family business, and you’re part of the family.
It’s not your job to know how to fix obscure problems with your chemistry analyzer. You serve patients. You’re responsible for a huge volume of data.
You never have to attempt a repair on your own. We’ll walk you through exactly what you need to do and we’ll stay on the line until you’re up and running.
That’s the work and the worry we take off your shoulders.
Learn more about your local service in California Get everything you need for your Roche Cobas or other analyzer in one placeYou shouldn’t have to cobble together parts and services from multiple suppliers to support your work.
With IDE, you get a curated collection of everything you need to run your Roche Cobas or other chemistry or immunochemistry system in one place.
Find everything you need below, or contact us and tell us what’s going wrong.
Don’t wait for a large service provider from out-of-state to triage your problem. Get it fixed now.
Trade in your instrument to save on your next refurbished system!Your lab may be shifting priorities.
Trade in the system you don’t want anymore and put the value toward an upgrade.
There’s always another lab that could use your old analyzer. We’ll rebuild it from the frame and ensure it continues to provide value to your colleagues somewhere else.
It’s a great way to maintain your lab’s low environmental impact and stop old materials from ending up in a landfill.
Plus, it will have a huge impact on the price of your upgrade.
Contact us to trade in your old instrument and save Service for your Roche Cobas in California Get everything, from parts to reagents to preventative maintenance and other service, in one place. Build a relationship and get the personal attention your lab wants. Don’t get treated like a number. Preventative maintenance Get ahead of impending errors and limit downtime. Tailored service agreements Don’t sign on for a one-size-fits-all solution. Choose a bespoke service agreement for your unique challenges. Same day phone support You don’t always need to wait for someone to come to you. Sometimes you just need to talk through your problem. Get that help today. Affordable depot service It costs money to send an engineer to your site. Instead, send your instruments to us for repairs, service, or refurbishment. Decontamination and relocation This isn’t like moving a couch. Get qualified help to move your valuable instruments. Installation, training, validation Get installation, IQ/OQ validation, onsite structural review, power connection, alignment validation, calibration and quality control. Plus, get professional training for lab technicians to safely and correctly use instruments and perform tests and basic maintenance (reducing your long term costs). We’re eager to help out. Contact us here todayTest Menu
COBAS c 501 Module | ||||
6AM | BILT3 | FEN2 | LPA2 | SVTCH |
A1C-3 | BUP | FERR4 | LSD | SVTCR |
A1MG2 | C3C-2 | FRA | MDN2 | SVTNI |
A2MG | C4-2 | GENTC | Methadone Metabolite | SVTOX |
AAGP2 | CA2 | GGT-2 | MG2 | SVTpH |
AAT2 | CARB4 | GLUC2 | MPA | SVTSG |
ACET2 | CERU | GLUC3 | MTQL | THC2 |
ALB2 | CHE | HAPT2 | MYO2 | THEO2 |
ALBP | CHE2 | HCYS | NAPA2 | TOBR2 |
ALP2 | CHOL2 | HDLC4 | NH3L | TP2 |
ALT | CK | HYD | NH3L2 | TPUC3 |
ALTL | CO2-L | IGA-2 | OPI2 | TRIGL |
ALTLP | COC2 | IGG-2 | OXY | TRSF2 |
AMIK 2 | CREJ2 | IGM-2 | PCP | UA2 |
AMPS2 | CREP2 | IRON2 | PHNO2 | UIBC |
AMY-P | CRP4 | ISE Chloride Electrode | PHNY2 | UREAL |
AMYL2 | CRPHS | ISE Potassium Electrode | PHOS2 | VALP2 |
APOAT | CRPLX | ISE Sodium Electrode | PPX | VANC3 |
APOBT | CYSC2 | KFLC | PREA | β2-Microglobulin |
ASLOT | D Bili | LACT2 | PROC2 | |
ASTL | D-DI | LDHI2 | QUIN2 | |
ASTLP | DIG | LDLC3 | RF-II | |
B2MG | EDDP | LFLC | SALI | |
BARB | ETOH2 | LI | SI2 | |
BENZ | FCAL | LIPC | STFR | |
COBAS e 601 Module | |||
Elecsys ACTH | Elecsys Cyclosporine | Elecsys Insulin | Elecsys Total-Tau CSF |
Elecsys AFP | Elecsys CYFRA 21-1 | Elecsys LH | Elecsys Toxo IgG |
Elecsys AMH | Elecsys DHEA-S | Elecsys Myoglobin | Elecsys Toxo IgM |
Elecsys Anti-CCP | Elecsys Digoxin | Elecsys N-MID Osteocalcin | Elecsys Troponin I |
Elecsys Anti-HAV | Elecsys Estradiol III | Elecsys NSE | Elecsys TSH |
Elecsys Anti-HAV IgM | Elecsys Ferritin | Elecsys PAPP-A | Elecsys Vitamin B12 II |
Elecsys Anti-HBc IgM | Elecsys Folate III | Elecsys Phospho-Tau (181P) CSF | Elecsys β -CrossLaps/serum |
Elecsys Anti-HBc II | Elecsys Folate RBC | Elecsys PlGF | |
Elecsys Anti-HBe | Elecsys free PSA | Elecsys proBNP II | |
Elecsys Anti-HCV II | Elecsys free βhCG | Elecsys Progesterone III | |
Elecsys Anti-SARS-CoV-2 S | Elecsys FSH | Elecsys ProGRP | |
Elecsys Anti-Tg | Elecsys FT3 III | Elecsys Prolactin II | |
Elecsys Anti-TPO | Elecsys HBeAg | Elecsys PTH | |
Elecsys Anti-TSHR | Elecsys HBsAg Confirmatory Test | Elecsys Rubella IgG | |
Elecsys BRAHMS PCT | Elecsys HBsAg II | Elecsys Rubella IgM | |
Elecsys C-Peptide | Elecsys HCG STAT | Elecsys S100 | |
Elecsys CA 125 II | Elecsys HCG+β | Elecsys SARS-CoV-2 Antigen | |
Elecsys CA 15-3 II | Elecsys HE4 | Elecsys sFlt-1 | |
Elecsys CA 19-9 | Elecsys hGH | Elecsys SHBG | |
Elecsys Calcitonin | Elecsys HSV-1 IgG | Elecsys Syphilis | |
Elecsys CEA | Elecsys HSV-2 IgG | Elecsys T-Uptake | |
Elecsys CK-MB | Elecsys IgE II | Elecsys T3 | |
Elecsys CMV IgG | Elecsys IGF-1 | Elecsys T4 | |
Elecsys CMV IgM | Elecsys IGFBP-3 | Elecsys Tacrolimus | |
Elecsys Cortisol II | Elecsys IL-6 | Elecsys Testosterone II | |
Elecsys total PSA |
COBAS 6000 TECHINCAL SPECIFICATION
Specifications
Manufacturer | Roche Diagnostics |
Condition | New |
System | 2nd Generation SWA: modular, analytical system platform, consolidated work area for Clinical Chemistry and Immunology, expandable and re-configurable on site |
Types of modules | · cobas c 501 module: Photometric measuring unit (incl. ISE) · cobas e 601 module: Electrochemiluminescence (ECL) technology measuring unit |
Number of configurations | 7 module combinations; Up to 3 modules in one core unit · cobas c 501 modules: 1 to 2 modules · cobas e 601 modules: 1 to 2 modules · cobas c 501 | cobas e 601 modules: 2 to 3 modules (only 2 units of 1 module type for SWA combinations possbile) |
Sample throughput | Up to 120 racks/hour or 600 samples/hour |
Test throughput (theoretical max) | · 170 up to 2,170 tests/hour: overall · 1,000 up to 2,000 tests/hour:with cobas c 501 modules · 170 up to 340 tests/hour:with cobas e 601 modules · 1,170 up to 2,170 tests/hour: with cobas c 501 and cobas e 601 modules |
Number of reagent channels (reagent slots) | Up to 151 channels, in total 63 channels (including ISE, automatic setting) on cobas c 501 module 25 channels on cobas e 601 module |
Sample material | Serum, Plasma, Urine, CSF |
Core unit analytics | · Rack: 5 position rack, RD standard rack · Rack types: Routine, STAT, Control, Calibrator, Rerun (manual), Wash · Tray: Tray with 15 racks/75 samples, RD standard tray · STAT port: STAT samples are processed with true STAT interrupt |
Sample container types | · Primary tubes: 5 to 10 mL; 16 x 100, 16 x 75, 13 x 100, 13 x 75 mm · Sample cup: 2.5 mL · Micro cup: 1.5 mL, (exception: cobas e 601 module) · Cups on tube: Cup on top of a 16 x 75/100 mm tube; Cup on top of one non standard tube · False bottom tube (FBT): One type is definable |
Sample volume | 1–35 µL |
Sample dilution | 3–121 times |
Sample clot detection | Available for cobas c 501 and cobas e 601 module |
Minimum sample volume | · Primary tubes: 700 µL · Sample cup: 100 µL · Micro cup (FTB): 50 µL |
Sample barcode types | Code 128; Codabar (NW 7); Interleaved 2 of 5; Code 39 |
System interfaces | RS 232 serial interface, bi-directional Interface to cobas link data station for cobas teleservice functionalities and automatic download |
Sample data base | 10.000 routine/STAT samples |
Test methods | For photometric modules: 1 point, 1 point + prozone check, 2 point, 2 point kinetic, 2 point + prozone check, 3 point, 1 point + kinetics Rate A, Rate A + serum index, Rate A with blank, Rate B |
Calibrator/QC input | Via specified racks through the input buffer or STAT port |
Calibration methods | Start-up, Re-calibration For photometric modules: Linear, non-linear multi-points, 2 point calibration, K-factor up to 100 different calibrators pre-programmable Storage of up to 180 curves Preventive calibration of the stand-by cobas c and cobas e packs on cobas c 501: Two k-factor can be defined for different sample types |
QC methods | For e- and photometric modules: Real-time QC, individual QC, cumulative QC Up to 100 controls pre-programmable Preventive QC after calibration of the stand-by cassettes/rack packs Auto QC: QC without operator intervention (timer triggered) |
Rerun/reflex function | Automatic rerun and manual rerun; Automatic reflex is supported by the system, reflex request to be provided by Roche Middleware Solutions |
Electrical requirements | · Power requirements: 230 Volts AC; 110 Volts AC 2.4 kVA (for cobas c 501 | e 601) · Frequency: 50 Hz or 60 Hz +/- 0.5% |
Water/waste requirements | · Water: Bacteria free, deionised water supply: resistance of < 1,0 µS/cm · Water pressure: 0.5 – 3.5 kg/cm3, (49–343 Kpa) · Biohazards waste: Separate container behind the system · L. concentrated: Central drain port, diameter: = 50 mm / 2 inches · Waste drain < waste: 100 mm above the floor / 4 inches |
Water consumption | · Max flow rate: cobas c 501 module: approx. 40 L/hour · Typical consumption: cobas e 601 module: approx. 30 L/hour |
Operational conditions | · Ambient temperature: 15 to 32°C / 59 to 90°F · Ambient humidity: 30 to 85% (RH, without condensation) · Heat output: 1.5 kW (5400 kJ/hr for cobas c 501, 4320 kJ/hr for cobas e 601) · Noise output: < 65 dB |
Physical dimensions | · Width: 188 to 498 cm / 74 to 196 inches · Core unit: 69 cm / 27.2 inches cobas c or cobas e module: 120 cm / 47.2 inches · Depth: cobas c or cobas e module: 98 cm / 38.6 inches Core unit: 104 cm / 41 inches · Height: 130 cm / 51 inches · Control unit: Width: 80 cm / 31.5 inches, depth: 80 cm / 31.5 inches |
Weight | · cobas c 501 module: 330 kg / 730 lbs · cobas e 601 module: 360 kg / 795 lbs · Core unit (sample loader, control unit, rack rotor): 180 kg / 400 lbs |