Randox RX Daytona + Chemistry/Toxicology Analyzer

Randox RX Daytona + Chemistry/Toxicology Analyzer

Contact us for price

Description

Includes:

  • One Randox RX Daytona

Overview:

The RX Daytona+ is a fully automated, random access platform delivering a high level of precision, accuracy, and reliability with the ability to perform emergency STAT sampling. It is the most versatile analyzer in its class, capable of performing 270 photometric tests per hour and up to 450 with ISE testing.

Features/Benefits:

  • Extensive Test Menu: Covers routine chemistries, specific proteins, lipids, antioxidants, cardiac, and diabetes testing, offering cost savings through consolidation of routine and novel tests on a single platform.
  • Barcode Integration & Optical Technology: Integrated barcode readers for reagent and sample identification. 12 wavelengths generated via diffraction grating (340–800 nm) allow a multitude of chemistries on one system.
  • Minimized Carryover: Separate sample and reagent pipettes reduce carryover. Dedicated micropipettes include liquid level sensors and crash detection. Dual five-speed stirrers provide optimized mixing for each assay.
  • Economic Platform: Low water consumption of only 5 liters per hour, saving on consumables. Requires minimal maintenance.
  • User-Friendly Software: Icon-based and advanced software with on-board inventory management provides unrivalled uptime, performance, sensitive clot detection sensors, and cuvette checking.
  • Advanced QC Capabilities: Improves laboratory efficiency with Levey-Jennings charts, calibration curves, QC statistics, results, and seven different calibration options.


Test Menu


Clinical

Cholesterol

Direct HDL Cholesterol

Cholesterol

Glycerol

CK-MB

Direct LDL Cholesterol

Creatinine Enzymatic

HbA1c/Hb

CK-NAC

Homocysteine

Creatinine (Jaffe)

Microalbumin

CRP

Lipoprotein (a)

Cystatin C

NEFA (Non-Esterified Fatty Acids)

CRP Full Range (0.3-160mg/l)

sdLDL

Direct HDL Cholesterol

Ranbut (Hydroxybutyrate)

CRP High Sensitivity

Triglycerides

Direct LDL Cholesterol

Total Protein

Fructosamine

Triglycerides

Glucose

Urinary Protein

Hepatic Function

Albumin

Glycerol

Aldolase

Haptoglobin

Alkaline Phosphatase

IgA

ALT

IgG

Ammonia

IgM

AST (GOT)

Iron (UIBC)

Bile Acids

LDH

Cholinesterase

sTfR

Complement Component 3

Total Bilirubin

Complement Component 4

Total Protein

Direct Bilirubin

Transferrin

Gamma GT

Transthyretin (Prealbumin)

GLDH

Lipids

Apolipoprotein A-I

Cholesterol

Apolipoprotein AII

Direct HDL Cholesterol

Apolipoprotein B

Direct LDL Cholesterol

Apolipoprotein CII

Lipoprotein (a)

Apolipoprotein CIII

sdLDL

Apolipoprotein E

Triglycerides

Comprehensive Metabolic Profile

Albumin

Creatinine (Jaffe)

Alkaline Phosphatase

Glucose

ALT

Lactate

AST (GOT)

Potassium

Direct Bilirubin

Sodium

Calcium

Total Bilirubin

Chloride

Total Protein

CO2 Total

Urea

Creatinine Enzymatic

Nutritional Status

Albumin

Magnesium

Copper

Potassium

Ferritin

TIBC

Iron

Transferrin

Iron (UIBC)

Transthyretin (Prealbumin)

Lipase

Zinc

Haemolytic Anaemia

G6PDH

LDH

Haptoglobin

Bone Profile

Alkaline Phosphatase

Phosphorus

Calcium

Total Protein

Veterinary

Albumin

Cholinesterase (Butyryl)

Iron (UIBC)

Sodium

Alkaline Phosphatase

CK-NAC

Lactate

Total Protein

ALT (GPT)

CO2 Total

Lactate Dehydrogenase

Triglycerides

Aldolase

Copper

LDL

Urea

Ammonia

Creatinine

Lipase

Uric Acid

Amylase

Canine CRP

Magnesium

Urinary Protein

AST (GOT)

CRP

NEFA (Non-esterified fatty acids)

Zinc

Bile Acids

Fructosamine

Phosphorus (Inorganic)

Bilirubin

Gamma-GT

Potassium

Calcium

GLDH

Ranbut (Hydroxybutyrate)

Chloride

Glucose

Ransel (Glutathione peroxidase)

Cholesterol

Glycerol

Ransod (Superoxide dismutase)

Therapeutic Drugs

Phenobarbital

Valproic Acid

Speciality / Drugs of Abuse

Ethanol

Specific Proteins

Apolipoprotein A-I

Complement Component 3

Haptoglobin

Rheumatoid Factor

Apolipoprotein AII

Complement Component 4

HbA1c/Hb

sTfR

Apolipoprotein B

CRP

IgA

Transferrin

Apolipoprotein CII

CRP Full Range (0.3-160mg/l)

IgE

Transthyretin (Prealbumin)

Apolipoprotein CIII

CRP High Sensitivity

IgG

Apolipoprotein E

Cystatin C

IgM

ASO

Ferritin

Lipoprotein (a)

Beta-2 Microglobulin

Fructosamine

Microalbumin

Antioxidants

Albumin

Glutathione Reductase

TIBC

Uric Acid

Bilirubin

Ransel (Glutathione Peroxidase)

Total Antioxidant Status

Ferritin

Ransod (Superoxide Dismutase)

Transferrin

Food & Wine Testing

Acetic Acid

Ethanol

Potassium

Ammonia

Glucose/Fructose

Total Antioxidant Status

Copper

Malic Acid

RX Unique Assays

Aldolase

Cholesterol (sdLDL-Cholesterol)

G6PDH

Microalbumin

Apolipoprotein C-II

Copper

Glutathione Peroxidase (Ransel)

Non-Esterified Fatty Acids (NEFA)

Apolipoprotein C-III

Creatinine (Enzymatic)

Glutathione Reductase

Soluble Transferrin Receptor (sTfR)

Apolipoprotein E

Cystatin C

Homocysteine

Superoxide Dismutase (Ransod)

Bile Acids (5th Generation)

D-3-Hydroxybutyrate (Ranbut)

IgE

Total Antioxidant Status (TAS)

Bilirubin (Vanadate Oxidation)

Fructosamine (Enzymatic)

Lipoprotein(a)

Zinc


Specifications

ConditionNew
Stock Number285
Height625mm
Depth670mm
Width870mm
Weight120kg
Throughput270 tests per hour, 450 tests per hour with ISE
Analyzer typeCompact fully automated random access bench top clinical analyzer
Assay typeEndpoint, kinetic and ISE
MaintenanceDaily maintenance – less than 5 minutes. Simple twice yearly preventative maintenance service
Data managementStorage of up to 30,000 patient reports, search facility
Test channels50 photometric channels, 3 direct ISE
Sleep modeUser defined sleep mode capabilities with automatic wash and instrument prep
Reagent pipetteDedicated reagent micropipette with liquid level sensor and crash detection
Reagent capacityRemovable turntable with 50 cooled positions for 20ml and 70ml bottles
Reagent cooling8 to 15°C
Reagent identificationBarcode reagent identification
Reagent inventoryCalculation of remaining reagent volume and tests available Alert for shortage or expired reagents
Sample additionSampling interruption for addition of samples
Sample capacity50 positions are contained within the universal carousel, including 10 bespoke positions for calibrators and controls
Sample dead volume150µl in standard or primary tubes, 100µl in paediatric cups
Sample dilutionPre-dilution and automatic re-assay with diluted, reduced or increased sample volume
Sample identificationBarcode sample identification
Sample pipetteDedicated sample micropipette with liquid level sensor, crash protection and clot detection
Sample tube sizeMultiple primary tube sizes (diameter 12 to 16mm, height 55 to 100mm), Paediatric cups
Sample typeSerum, Plasma, Urine, CSF & Whole Blood Sample volume 1.5 to 35µl (0.1µl increments)
STAT samplingSTAT samples can be added immediately via emergency loading port 11
Reaction time10 minutes (R1: 5 min. + R2: 5 min.)
Reaction volume100 to 350µl
Stirring speed5 speed levels available
Stirring systemDual 5 speed stick type rotating stirrers
Temperature controlDry bath
Water consumptionMaximum 5L per hour
Water requirementsNCCLS type 1 or 2 purified water supply
Wash unit12 stage washing process
Cuvettes72 semi-permanent cuvettes
Incubator temperature37°C ± 0.1°C
Cycle time13 seconds
Detector methodDirect absorbance in cuvette (bi-chromatic and monochromatic)
Detection principal12 wavelengths generated via diffraction grating: 340, 380, 415, 450, 510, 546, 570, 600, 660, 700, 750 and 800nm
ISE unitOptional ISE unit available
Light sourceHalogen tungsten lamp air cooled by fan
Quality controlInteractive Levey-Jennings charts, daily, monthly and batch QC with data archiving
Calibration principalFactor, Linear, Point to point, Log-logit, Exponential, Spline and Spline 2
Power requirementAC100V to 120V, 6.5A (Max.) AC200 to 230V, 3.3A (Max.) 50/60Hz
Power consumption650VA
Permissible voltage variation± 10% (Max.)
LIMS connectivityBi-directional ASTM Standard (RS232 connection)
Operator interfaceWindows10® based software