Dynex DS2 Automated ELISA Processing System

Dynex DS2 Automated ELISA Processing System

Contact us for price

Description

Dynex DS2 Automated ELISA Processing System 

Run any assay from any vendor

  • Fully automated open system
  • Ability to bring in tests that are currently being sent out
  • Automated sample distribution, incubation, reagent addition, washing and detection steps of assays as defined by the manufacturer. The lab can customize assay parameters, assay steps, OD read settings, result calculations, quality control checks and report formats with ease
  • Reliable workload scheduling

  • For the past 2 years DYNEX DS2 has achieved 98.5 uptime when mean time between failure target is set at 250 days
  • Schedule your preventive maintenance during slow period
  • Electronic Signature Pipetting (ESP) is a sophisticated technique used by the DS2 for detection of gross pipetting errors often caused by the presence of particulate matter, clots, foam, or bubbles in the sample. Insufficient sample transfer can therefore be detected and reported to the operator during a run
  • Prevent unscheduled down time
  • Saves Space

  • The DS2 system footprint is less than four square feet of linear counter space to process up to two 96-well microplates and 100 specimens making it ideal for lab’s expanding workload
  • Utilize the same linear space as manual incubator and reader
  • The innovative DS2 is designed for clinical, research and industrial labs that want to enhance their processes through automation. Installed in over 3,500 labs worldwide, the DS2 is the solution for the rigorous, repeatable analyses required in critical applications including immunology, infectious disease, hormone, allergy, blood-chemistry, drugs-of-abuse testing, food safety, forensics, and environmental testing among others.

    Physical Specifications Dimensions      Metric          Non Metric System Specifications 40 mm – 100 mm height Up to 10 (15 mL tubes) Number of Reader Specifications < 2% CV (2.0 – 3.0 OD) (0.000 – 3.000 OD) whichever is greater Washer Specification Incubator Specifications 14 – 20 Hz (periodic or continuous) Reagent Pipetting Specifications 20 uL (single-shot mode) Sample Pipetting Specifications 10 uL (single-shot mode) 1 part in 39,601 two-stage dilution Process Security Software

    Specifications

    ConditionNew
    Width54 cm            21 in
    Depth68 cm             27 in
    Height66 cm             26 in
    Footprint0.36 sq m         3.9 sq ft
    Bench Weight48 kg            105 Ib
    Ship Weight78 kg             170lb
    NoiseNoise output     < 78 dB
    Number of Plates2
    Sample Capacity100 per load
    Continuous Sample LoadingYes
    Sample Tube Size10 mm – 16 mm diameter
    Number of ReagentsUp to 8 (25 mL tubes)
    Standard/Control Bottles24 (2 mL vials)
    Assays per PlateUp to 12
    Dilution Wells CapacityUp to 96 deep-well strips (12 x 8)
    Sample Tip Capacity216 tips (2 x 108)
    Reagent Tip Capacity20 tips
    Photometric Range0.100 – 3.0 OD
    Spectral Range405 nm – 690 nm
    Filter Slots6 wavelength
    Precision< 1% CV (< 2.0 OD)
    Accuracy± 0.005 OD or 2.5
    Read Time< 30 sec (single wavelength)
    Manifold Configuration8-way
    Programmable Volumes50 µL – 1,000 µL
    Wash Buffer Capacity2 wash bottles at 2 L, with level-sensing
    Residual Wash Volume< 3 µL with super sweep
    Dispense Precision≤ 5% CV (with 300 μL in a 96 well plate)
    Waste Container1 x 1.5 L
    Number of Incubators2
    Temperature RangeAmbient + 4° C to 40° C
    Temperature Accuracy± 1° C across plate @ 37° C
    ShakingIndependent linear motion
    Temperature MonitoringYes
    Reagent Tip Size1,300 µL
    Reagent Pipetting Volume20 μL – 1,000 μL
    Precision, Reagent Tip< 3% CV at any operating volume above
    Sample Tip Size300 μL
    Sample Pipetting Volume10 μL – 250 μL
    Sample Pipetting Precision< 3% CV at any operating volume above
    Dilution Range1 part in 199 one-stage dilution
    Liquid Level SensingYes (reagents, controls and samples)
    Level Sensor SystemPressure di erential
    Clot DetectionYes
    Dispense Anomaly DetectionYes
    Tip DetectionYes
    Electronic Signature PipettingYes
    AlarmsYes
    Controlling SoftwareDS-Matrix
    Work Protocols (Assays)Unlimited
    Data ProcessingQuantitative and qualitative
    Levey-JenningsYes
    Westgard RulesYes
    Process ReportingEvent log + error log
    Automatic Error RecoveryYes
    Password Access ControlYes