Beckman Coulter / Olympus AU 480 Chemistry Analyzer

Beckman Coulter / Olympus AU 480 Chemistry Analyzer
Contact us for price
or
Call 951.296.1266
Description
Beckman Coulter / Olympus AU480 Chemistry Analyzer
The AU480 chemistry analyzer is the ideal main analyzer for small- to medium-sized laboratories/Hospitals, with a throughput of up to 800 tests per hour with ISE and simultaneous programming for up to 63 different analytes. The Olympus AU 480 chemistry analyzer can be used as a special chemistry or STAT analyzer in any laboratory.
Robust testing capabilities
Efficient reagent and consumable use
Convenient operational features
Features
Robust testing capabilities
Efficient reagent and consumable use
Convenient operational features
Test Menu
Acetaminophen | D-Dimer | Phosphorus |
ALT | Digoxin | Prealbumin |
Albumin | Disopyramide | Primidone |
Alcohol | Ecstasy | Procainamide |
ALP | Ethosuximide | Propoxyphene |
a1-acid glycoprotein | Ferritin | Quinidine |
a1-antitrypsin | Fructosamine | Rheumatoid Factor |
Amikacin | GGT | Salicylate |
Ammonia | Gentamicin | T-Uptake |
Amphetamine | Glucose | Theophylline |
Amylase | Haptoglobin | Thyroxin, Total |
Anti-strepolysin O | HDL Cholesterol, Direct | Tobramycin |
Apolipoprotein A1 | Hemoglobin A1c | Transferrin |
Apolipoprotein B | IgA | Triglyceride |
AST | IgG | UIBC |
Barbiturate | IgM | Urea Nitrogen |
Benzodiazepine | Iron | Uric Acid |
B2 Microglobulin | Lactate Dehydrogenase | Valproic Acid |
Bicarbonate | Lactate | Vancomycin |
Bilirubin, Direct | LDL Cholesterol, Direct | |
Bilirubin, Total | Lidocaine | |
CRP, hs | Lipase | |
CRP | Lithium | |
C3 Complement | LSD | |
C4 Complement | Magnesium | |
Caffeine | Methadone | |
Calcium | Methaqualone | |
Carbamazepine | Methotrexate | |
Ceruloplasmin | Microalbumin | |
Chloride | N-Acetylprocainamide | |
Cholinesterase | Opiate Metabolite | |
Cocaine Metabolite | Oxycodone | |
CK-MB | Phencyclidine (PCP) | |
CK-NAC | Phenobarbital | |
Creatinine | Phenytoin |
Specifications
Manufacturer | Beckman Coulter, Olympus |
Condition | New |
Analytical Principle | Spectrophotometry and potentiometry |
Analytical Types | Endpoint, rate, fixed point and indirect ISE |
Analytical Methods | Colorimetry, turbidimetry, latex agglutination, homogeneous EIA, indirect ISE |
Simultaneously Processed Analytes | 60 photometric tests + 3 ISE, 120 pre-programmed onboard tests |
Throughput | 400 photometric tests/hour; maximum of 800 with ISE |
ISE Throughput | 200 samples/hr. Maximum tests/hr: 600 if ISE only |
Sample Feeder | Racks with 10 samples each (barcodes on primary tubes and on racks); capacity of 80 samples; continuous loading |
Sample Tubes | Primary and secondary tubes; diameter from 11.5 to 16 mm; height from 55 to 102 mm, nestled micro sample cups |
STAT samples | Up to 22 positions for STAT samples via cooled turntable. Easy-to-operate interrupts between tests. Auto-repeat run capability. |
Reagent Capacity | 76 positions for (R1+R2, detergent position). Holds 15, 30 and 60ml bottles. |
Sample Types | Serum, plasma, urine, other |
Reagent Volume | R1: 10–250 μl; R2: 10–250 μl (in 1 μl increment) |
Photometry System | Direct assay through the reaction cuvette (0–3.0 OD) mono and bichromatic measurements possible |
Sample Volume | 1–25 μl in 0.1 μl steps (1-25 μl for repeats) |
Calibration | Auto calibration, cooled calibrator positions; master calibration established by two-dimensional barcode |
Sample Pre-dilution | Dilution ratio: Fixed to 3, 5, 10, 15, 20, 25, 50, 76 or 100 |
Test Requisition | Individual and profile test requisition via online, mouse, function keys and touch-screen |
Sample Integrity | Lipaemia, Haemolysis and Icterus analysis. Sample clot detection and probe crash protection. |
Online | RS232C. Full uni- and bidirectional communication possible. |
Reagent Storage | Refrigerated (4–12°C) |
Data Storage | Sample number 100,000 samples. Reaction Data 200,000 tests. |
Dimensions (W x H x D) | ANL: 1,450 x 1,205 x 760 |
Total Reaction Volume | 90–350 μl |
Reaction Cuvette | Permanent glass cuvettes |
Reaction Time | Up to 8 minutes, 37.5 seconds |
Reaction Incubation | 37°C, dry bath |
Wavelength | 13 different wavelengths between 340–800 nm |
Quality Control | Auto QC, cooled QC positions |
Rerun | 1. Auto rerun and manual rerun available |
Software | Windows 7® |
Power Supply | 100–240v; 60 Hz/ < 3.5 kVA |
Analytical System | Fully automated, random access chemistry system with STAT capability |