Beckman Coulter / Olympus AU 480 Chemistry Analyzer

Beckman Coulter / Olympus AU 480 Chemistry Analyzer

Contact us for price

Description

Beckman Coulter / Olympus AU480 Chemistry Analyzer 

The AU480 chemistry analyzer is the ideal main analyzer for small- to medium-sized laboratories/Hospitals, with a throughput of up to 800 tests per hour with ISE and simultaneous programming for up to 63 different analytes. The Olympus AU 480 chemistry analyzer can be used as a special chemistry or STAT analyzer in any laboratory.

Robust testing capabilities

  • Broaden your test offerings with more than 120 different Beckman Coulter system reagent applications available
  • Conduct quick priority testing using the AU 480 clinical chemistry analyzer’s STAT wheel
  • Turn around critical samples fast with sample pre-dilution and auto-repeat of over-range results
  • Efficient reagent and consumable use

  • Minimize hands-on time and reduce daily reagent inventory tasks with ready-to-use liquid concentrated reagents
  • Experience lower total cost of ownership with low consumable requirements
  • Convenient operational features

  • Provide the right operator support when needed using context-sensitive help screens and instructional videos
  • Simplify operations with user-friendly graphical user interface design and touch-screen monitor
  • Reduce tech-to-tech variation and achieve consistent result quality with AU family of chemistry analyzers’ standardized processes
  •  

    Features

    Robust testing capabilities

  • Broaden your test offerings with more than 120 different Beckman Coulter system reagent applications available
  • Conduct quick priority testing using the analyzer’s STAT wheel
  • Turn around critical samples fast with sample pre-dilution and auto-repeat of over-range results
  • Efficient reagent and consumable use

  • Minimize hands-on time and reduce daily reagent inventory tasks with ready-to-use liquid concentrated reagents
  • Experience lower total cost of ownership with low consumable requirements
  • Convenient operational features

  • Provide the right operator support when needed using context-sensitive help screens and instructional videos
  • Simplify operations with user-friendly graphical user interface design and touch-screen monitor
  • Reduce tech-to-tech variation and achieve consistent result quality with AU family of chemistry analyzers’ standardized processes
  • Test Menu

    Acetaminophen D-Dimer Phosphorus
    ALT Digoxin Prealbumin
    Albumin Disopyramide Primidone
    Alcohol Ecstasy Procainamide
    ALP Ethosuximide Propoxyphene
    a1-acid glycoprotein Ferritin Quinidine
    a1-antitrypsin Fructosamine Rheumatoid Factor
    Amikacin GGT Salicylate
    Ammonia Gentamicin T-Uptake
    Amphetamine Glucose Theophylline
    Amylase Haptoglobin Thyroxin, Total
    Anti-strepolysin O HDL Cholesterol, Direct Tobramycin
    Apolipoprotein A1 Hemoglobin A1c Transferrin
    Apolipoprotein B IgA Triglyceride
    AST IgG UIBC
    Barbiturate IgM Urea Nitrogen
    Benzodiazepine Iron Uric Acid
    B2 Microglobulin Lactate Dehydrogenase Valproic Acid
    Bicarbonate Lactate Vancomycin
    Bilirubin, Direct LDL Cholesterol, Direct
    Bilirubin, Total Lidocaine
    CRP, hs Lipase
    CRP Lithium
    C3 Complement LSD
    C4 Complement Magnesium
    Caffeine Methadone
    Calcium Methaqualone
    Carbamazepine Methotrexate
    Ceruloplasmin Microalbumin
    Chloride N-Acetylprocainamide
    Cholinesterase Opiate Metabolite
    Cocaine Metabolite Oxycodone
    CK-MB Phencyclidine (PCP)
    CK-NAC Phenobarbital
    Creatinine Phenytoin
    2. Automatic sample increase, decrease or normal repeat 3. Reflex testing

    Specifications

    ManufacturerBeckman Coulter, Olympus
    ConditionNew
    Analytical PrincipleSpectrophotometry and potentiometry
    Analytical TypesEndpoint, rate, fixed point and indirect ISE
    Analytical MethodsColorimetry, turbidimetry, latex agglutination, homogeneous EIA, indirect ISE
    Simultaneously Processed Analytes60 photometric tests + 3 ISE, 120 pre-programmed onboard tests
    Throughput400 photometric tests/hour; maximum of 800 with ISE
    ISE Throughput200 samples/hr. Maximum tests/hr: 600 if ISE only
    Sample FeederRacks with 10 samples each (barcodes on primary tubes and on racks); capacity of 80 samples; continuous loading
    Sample TubesPrimary and secondary tubes; diameter from 11.5 to 16 mm; height from 55 to 102 mm, nestled micro sample cups
    STAT samplesUp to 22 positions for STAT samples via cooled turntable. Easy-to-operate interrupts between tests. Auto-repeat run capability.
    Reagent Capacity76 positions for (R1+R2, detergent position). Holds 15, 30 and 60ml bottles.
    Sample TypesSerum, plasma, urine, other
    Reagent VolumeR1: 10–250 μl; R2: 10–250 μl (in 1 μl increment)
    Photometry SystemDirect assay through the reaction cuvette (0–3.0 OD) mono and bichromatic measurements possible
    Sample Volume1–25 μl in 0.1 μl steps (1-25 μl for repeats)
    CalibrationAuto calibration, cooled calibrator positions; master calibration established by two-dimensional barcode
    Sample Pre-dilutionDilution ratio: Fixed to 3, 5, 10, 15, 20, 25, 50, 76 or 100
    Test RequisitionIndividual and profile test requisition via online, mouse, function keys and touch-screen
    Sample IntegrityLipaemia, Haemolysis and Icterus analysis. Sample clot detection and probe crash protection.
    OnlineRS232C. Full uni- and bidirectional communication possible.
    Reagent StorageRefrigerated (4–12°C)
    Data StorageSample number 100,000 samples. Reaction Data 200,000 tests.
    Dimensions (W x H x D)ANL: 1,450 x 1,205 x 760
    Total Reaction Volume90–350 μl
    Reaction CuvettePermanent glass cuvettes
    Reaction TimeUp to 8 minutes, 37.5 seconds
    Reaction Incubation37°C, dry bath
    Wavelength13 different wavelengths between 340–800 nm
    Quality ControlAuto QC, cooled QC positions
    Rerun1. Auto rerun and manual rerun available
    SoftwareWindows 7®
    Power Supply100–240v; 60 Hz/ < 3.5 kVA
    Analytical SystemFully automated, random access chemistry system with STAT capability