Beckman Coulter / Olympus AU640e Chemistry Analyzer

Beckman Coulter / Olympus AU640e Chemistry Analyzer

Contact us for price

Description

Olympus AU640e Chemistry Analyzer

Fully automated, for routine, STAT, urine and homogeneous immunoassays Olympus standardizes chemistry immuno testing from 400 to 6,600 tests per hour for low to very high volume laboratories. This translates to higher productivity, increased efficiency and greater cost savings for your lab.

Test Menu Column 1

Acetaminophen

ALT

Albumin

Alcohol

ALP

a1-acid glycoprotein

a1-antitrypsin

Amikacin

Ammonia

Amphetamine

Amylase

Anti-strepolysin O

Apolipoprotein A1

Apolipoprotein B

AST

Barbiturate

Benzodiazepine

B2 Microglobulin

Bicarbonate

Bilirubin, Direct

Bilirubin, Total

CRP, hs

CRP

C3 Complement

C4 Complement

Caffeine

Calcium

Carbamazepine

Ceruloplasmin

Chloride

Cholinesterase

Cocaine Metabolite

CK-MB

CK-NAC

Creatinine


Test Menu Column 2

D-Dimer

Digoxin

Disopyramide

Ecstasy

Ethosuximide

Ferritin

Fructosamine

GGT

Gentamicin

Glucose

Haptoglobin

HDL Cholesterol, Direct

Hemoglobin A1c

IgA

IgG

IgM

Iron

Lactate Dehydrogenase

Lactate

LDL Cholesterol, Direct

Lidocaine

Lipase

Lithium

LSD

Magnesium

Methadone

Methaqualone

Methotrexate

Microalbumin

N-Acetylprocainamide

Opiate Metabolite

Oxycodone

Phencyclidine (PCP)

Phenobarbital

Phenytoin


Test Menu Column 3

Phosphorus

Prealbumin

Primidone

Procainamide

Propoxyphene

Quinidine

Rheumatoid Factor

Salicylate

T-Uptake

Theophylline

Thyroxin, Total

Tobramycin

Transferrin

Triglyceride

UIBC

Urea Nitrogen

Uric Acid

Valproic Acid

Vancomycin


capability, Urine and homogenous Immuno Assays. racks); capacity of 150 samples; continuous loading height from 55 to 102 mm, nestled micro sample cups refrigerated. Auto repeat run capability (4˚C-12˚C) bichromatic measurements possible Quality Control Auto QC, cooled QC positions function keys and touch screen probe crash protection

Specifications

ManufacturerBeckman Coulter, Olympus
ConditionNew
Stock Number256
Analytical SystemFully automated, random access chemistry system with STAT
Analytical MethodsEndpoint, kinetic rate, fixed rate, optionally ISE
Simultaneously Processed Analytes48 photometric tests + 3 ISE
Throughput800 photometric test/hour; maximum of 1,200 with ISE
Sample FeederRacks with 10 samples each (barcodes on primary tubes and on
Sample TubesPrimary and Secondary tubes; diameter from 11.5 to 16mm;
STAT Samples22 user-definable for STAT, QC, Cal, routines, enclosed and
Sample Volume2-50 µl [0.5 µl increments]
Reagent VolumeR1 and R2: 25-300 µl [1 µl increments]
Reagent Supply & StorageR1 = 48, R2 = 48; holds 15, 30, and 60ml bottles; refrigerated
Total Reaction Volume150 – 550 µl
Reaction CuvetteNondisposable glass cuvette
Reaction TimeUp to 8 min. + 15 sec.
Reaction Temperature37˚C, dry bath
Mixing MethodWith rotating paddles after dispensing sample and reagent
Photometry SystemDirect assay through the reaction cuvette (0-2.5 OD) mono or
Wavelength13 different wavelengths between 340 – 800 nm
Cuvette CleaningComprehensive cleaning with detergents
CalibrationAuto calibration, cooled calibrator positions
Sample IntegrityLipemia, Hemolysis, Icterus analysis. Sample clot detection and
Test RequisitionIndividual and profile test requisition via on-line, mouse,
Dimensions(W x H x D) mm ANL: 1,850 x 1,210 x 800
OnlineFull uni- and bidirectional communication possible
SoftwareWindows 2000
Power SupplyToshiba 1600XP 3.6kVA