Olympus AU640e Chemistry Analyzer
Fully automated, for routine, STAT, urine and homogeneous immunoassays Olympus standardizes chemistry immuno testing from 400 to 6,600 tests per hour for low to very high volume laboratories. This translates to higher productivity, increased efficiency and greater cost savings for your lab.
Test Menu Column 1
Acetaminophen
ALT
Albumin
Alcohol
ALP
a1-acid glycoprotein
a1-antitrypsin
Amikacin
Ammonia
Amphetamine
Amylase
Anti-strepolysin O
Apolipoprotein A1
Apolipoprotein B
AST
Barbiturate
Benzodiazepine
B2 Microglobulin
Bicarbonate
Bilirubin, Direct
Bilirubin, Total
CRP, hs
CRP
C3 Complement
C4 Complement
Caffeine
Calcium
Carbamazepine
Ceruloplasmin
Chloride
Cholinesterase
Cocaine Metabolite
CK-MB
CK-NAC
Creatinine
Test Menu Column 2
D-Dimer
Digoxin
Disopyramide
Ecstasy
Ethosuximide
Ferritin
Fructosamine
GGT
Gentamicin
Glucose
Haptoglobin
HDL Cholesterol, Direct
Hemoglobin A1c
IgA
IgG
IgM
Iron
Lactate Dehydrogenase
Lactate
LDL Cholesterol, Direct
Lidocaine
Lipase
Lithium
LSD
Magnesium
Methadone
Methaqualone
Methotrexate
Microalbumin
N-Acetylprocainamide
Opiate Metabolite
Oxycodone
Phencyclidine (PCP)
Phenobarbital
Phenytoin
Test Menu Column 3
Phosphorus
Prealbumin
Primidone
Procainamide
Propoxyphene
Quinidine
Rheumatoid Factor
Salicylate
T-Uptake
Theophylline
Thyroxin, Total
Tobramycin
Transferrin
Triglyceride
UIBC
Urea Nitrogen
Uric Acid
Valproic Acid
Vancomycin
capability, Urine and homogenous Immuno Assays. racks); capacity of 150 samples; continuous loading height from 55 to 102 mm, nestled micro sample cups refrigerated. Auto repeat run capability (4˚C-12˚C) bichromatic measurements possible Quality Control Auto QC, cooled QC positions function keys and touch screen probe crash protection
Specifications
| Manufacturer | Beckman Coulter, Olympus |
| Condition | New |
| Stock Number | 256 |
| Analytical System | Fully automated, random access chemistry system with STAT |
| Analytical Methods | Endpoint, kinetic rate, fixed rate, optionally ISE |
| Simultaneously Processed Analytes | 48 photometric tests + 3 ISE |
| Throughput | 800 photometric test/hour; maximum of 1,200 with ISE |
| Sample Feeder | Racks with 10 samples each (barcodes on primary tubes and on |
| Sample Tubes | Primary and Secondary tubes; diameter from 11.5 to 16mm; |
| STAT Samples | 22 user-definable for STAT, QC, Cal, routines, enclosed and |
| Sample Volume | 2-50 µl [0.5 µl increments] |
| Reagent Volume | R1 and R2: 25-300 µl [1 µl increments] |
| Reagent Supply & Storage | R1 = 48, R2 = 48; holds 15, 30, and 60ml bottles; refrigerated |
| Total Reaction Volume | 150 – 550 µl |
| Reaction Cuvette | Nondisposable glass cuvette |
| Reaction Time | Up to 8 min. + 15 sec. |
| Reaction Temperature | 37˚C, dry bath |
| Mixing Method | With rotating paddles after dispensing sample and reagent |
| Photometry System | Direct assay through the reaction cuvette (0-2.5 OD) mono or |
| Wavelength | 13 different wavelengths between 340 – 800 nm |
| Cuvette Cleaning | Comprehensive cleaning with detergents |
| Calibration | Auto calibration, cooled calibrator positions |
| Sample Integrity | Lipemia, Hemolysis, Icterus analysis. Sample clot detection and |
| Test Requisition | Individual and profile test requisition via on-line, mouse, |
| Dimensions | (W x H x D) mm ANL: 1,850 x 1,210 x 800 |
| Online | Full uni- and bidirectional communication possible |
| Software | Windows 2000 |
| Power Supply | Toshiba 1600XP 3.6kVA |