Awareness Technology Stat Fax 3300 Chemistry Analyzer

Awareness Technology Stat Fax 3300 Chemistry Analyzer

Contact us for price

Description

The Awareness Technology Stat Fax 3300 Microplate Reader is designed to read and calculate the results of in-vitro diagnostic assays. Equipped with a large graphical display, the reader provides absorbance and concentration readings at or near the available wavelength. The flexible Stat Fax 3300 is equipped with multiple, self-prompting operating modes to meet the varying demands and requirements of any facility. The modes include Absorbance Mode, Standard Mode, Rate Mode, Factor Mode, Multi-point Mode, and Index Mode. Moreover, the instrument accepts standard 12 mm round tubes as well as 1 cm square cuvettes.



Features/Benefits

  • Optical system temperature controlled to 37 C
  • Bi-chromatic with 6 filters and spaces for 2 optional additional filters (340-700nm)
  • Adapts for use with 12mm round tubes, 1cm square cuvettes, or built-in flow cell
  • Vacuum system speeds sampling and reduces carryover
  • Calibration traceable to NIST standard
  • Use the optional external keyboard for easy entry of patient names and data
  • Use Redi-Check to monitor accuracy, linearity, and repeatability the easy way
  • Peltier cell cooling available as an option
  • View kinetic plots in real time
  • Calculate kinetic results based on the entire read time OR the segment you choose.


Stat Fax 3300 stores patient data

  • Create a work list.
  • Run the tests.
  • Print Patient Reports.


Output data to:

  • On-board 40-column
  • Thermal printer
  • External printer
  • PC and LIS.


Stat Fax 3300 stores control values

  • and of fers many QC options to assure linear kinetics and reliable results.
  • Create Levey-Jennings plots for QC


Stat Fax 3300 stores calibrations and standard curves

  • For each run, choose a new curve or use a stored curve with options to revert to the previous curve and to modify multi- point curves.


Specifications

ManufacturerAwareness Technology
ConditionNew
Stock Number124
Spectrophotometer TypeFilter photometer
Optical ConfigurationSingle beam with continuously rotating filter wheel Monochromatic or bichromatic reading 8 filter positions
Usable Spectral Range330 to 770 nm
System ProceduresOpen and by stored menu
Calculating ModesAbsorbance, Single Standard, Factor Mode, Multi Standard Mode (up to 7 standards), Multi Standard % Abs (up to 7 standards), Kinetic Mode, Index Mode
Channels120 Open
Source of RadiationTungsten Halogen, 10 Watt, with automatic lamp saver
Selection of WavelengthBy filter
Filter Type4-cavity interference, long-life ion beam-assisted deposition
Wavelength Accuracy+/- 3 nm
Filter LocationAfter sample (heat absorbing filter before sample)
Filter SelectionAutomatic by software or via keyboard
Wavelengths340, 405, 505, 545, 580, 630 nm supplied standard, other/additional filters optional
Half Bandwidth< 10 nm
1/100 Bandwidth14 nm at 340 nm
False Radiant Energy Ratio< 0.001 at 340 and 405 nm
Cuvette1 cm square, 12 cm round, flow through
Supplied Typeflow through
Material316 stainless, borosilicate windows
GeometryCylindrical, 2.3 mm dia x 5 mm +/- 0.05 mm
Illuminated Volume21 µl
Minimum Read Volume250 µl
Aspiration/PurgeVacuum pump at 18 cm of Hg
ValveSilicone pinch type
Cuvette HolderThermostatically controlled compartment at 37° C
DetectorGallium-Arsenide-Phosphide photodiode
Display Type240 x 128 Graphic LCD w/ Backlight
Absorbance-0.5 to 3.5 (flow-through mode) -0.5 to 2.5 (tube or 1 cm cuvette)
ConcentrationMaximum 999,999
Kinetic ResultsAbs/min with resolution of 0.0002 A/min
Zero CompensationAutomatic
Range-0.5 to 2.5 absorbance
ParallelCentronics/IBM-PC compatible
SerialRS-232 at 9600 baud, 8 data, 1 stop, no parity Bi-Directional
Data Input1) 20 Key Keypad, 2) PS2 101 Keyboard (connector available at back of instrument)
Flow-through< 0.5 % at 1 absorbance, 340/630 nm
StabilityBetter than 0.003 A/hr monochromatic after warm-up Better than 0.001 A/hr bichromatic after warm-up
Warm-up Time90 seconds photometric 15 minutes for temperature compartment
ElectronicsZ180 Microprocessor 18 MHz 128k EEPROM 32 K bytes Nonvolatile RAM (NVRAM)
PowerAuto-Switching Power Supply Voltage source: 90 – 264 VAC Frequency: 50/60 Hz Power consumption: 60 watts Installation Category: CAT II Fuses: 2.5A/250V Fast 5-20 mm Glass Fuse, 2.0A/250V Fast 5-20 mm Ceramic Fuse, (2) 6/10 250V Slow Blow 3AG Fuses
Dimensions and Weight40cm (L) x 37 cm (W) x 14 cm (H) lid closed (30 cm lid opened), 6.4 kg