Awareness Technology Stat Fax 3300 Chemistry Analyzer

Awareness Technology Stat Fax 3300 Chemistry Analyzer
$3,750
Description
The Awareness Technology Stat Fax 3300 Microplate Reader is designed to read and calculate the results of in-vitro diagnostic assays. Equipped with a large graphical display, the reader provides absorbance and concentration readings at or near the available wavelength. The flexible Stat Fax 3300 is equipped with multiple, self-prompting operating modes to meet the varying demands and requirements of any facility. The modes include Absorbance Mode, Standard Mode, Rate Mode, Factor Mode, Multi-point Mode, and Index Mode. Moreover, the instrument accepts standard 12 mm round tubes as well as 1 cm square cuvettes.
Features/Benefits
- Optical system temperature controlled to 37 C
- Bi-chromatic with 6 filters and spaces for 2 optional additional filters (340-700nm)
- Adapts for use with 12mm round tubes, 1cm square cuvettes, or built-in flow cell
- Vacuum system speeds sampling and reduces carryover
- Calibration traceable to NIST standard
- Use the optional external keyboard for easy entry of patient names and data
- Use Redi-Check to monitor accuracy, linearity, and repeatability the easy way
- Peltier cell cooling available as an option
- View kinetic plots in real time
- Calculate kinetic results based on the entire read time OR the segment you choose.
Stat Fax 3300 stores patient data
- Create a work list.
- Run the tests.
- Print Patient Reports.
Output data to:
- On-board 40-column
- Thermal printer
- External printer
- PC and LIS.
Stat Fax 3300 stores control values
- and of fers many QC options to assure linear kinetics and reliable results.
- Create Levey-Jennings plots for QC
Stat Fax 3300 stores calibrations and standard curves
- For each run, choose a new curve or use a stored curve with options to revert to the previous curve and to modify multi- point curves.
Specifications
| Manufacturer | Awareness Technology |
| Condition | New |
| Stock Number | 124 |
| Spectrophotometer Type | Filter photometer |
| Optical Configuration | Single beam with continuously rotating filter wheel Monochromatic or bichromatic reading 8 filter positions |
| Usable Spectral Range | 330 to 770 nm |
| System Procedures | Open and by stored menu |
| Calculating Modes | Absorbance, Single Standard, Factor Mode, Multi Standard Mode (up to 7 standards), Multi Standard % Abs (up to 7 standards), Kinetic Mode, Index Mode |
| Channels | 120 Open |
| Source of Radiation | Tungsten Halogen, 10 Watt, with automatic lamp saver |
| Selection of Wavelength | By filter |
| Filter Type | 4-cavity interference, long-life ion beam-assisted deposition |
| Wavelength Accuracy | +/- 3 nm |
| Filter Location | After sample (heat absorbing filter before sample) |
| Filter Selection | Automatic by software or via keyboard |
| Wavelengths | 340, 405, 505, 545, 580, 630 nm supplied standard, other/additional filters optional |
| Half Bandwidth | < 10 nm |
| 1/100 Bandwidth | 14 nm at 340 nm |
| False Radiant Energy Ratio | < 0.001 at 340 and 405 nm |
| Cuvette | 1 cm square, 12 cm round, flow through |
| Supplied Type | flow through |
| Material | 316 stainless, borosilicate windows |
| Geometry | Cylindrical, 2.3 mm dia x 5 mm +/- 0.05 mm |
| Illuminated Volume | 21 µl |
| Minimum Read Volume | 250 µl |
| Aspiration/Purge | Vacuum pump at 18 cm of Hg |
| Valve | Silicone pinch type |
| Cuvette Holder | Thermostatically controlled compartment at 37° C |
| Detector | Gallium-Arsenide-Phosphide photodiode |
| Display Type | 240 x 128 Graphic LCD w/ Backlight |
| Absorbance | -0.5 to 3.5 (flow-through mode) -0.5 to 2.5 (tube or 1 cm cuvette) |
| Concentration | Maximum 999,999 |
| Kinetic Results | Abs/min with resolution of 0.0002 A/min |
| Zero Compensation | Automatic |
| Range | -0.5 to 2.5 absorbance |
| Parallel | Centronics/IBM-PC compatible |
| Serial | RS-232 at 9600 baud, 8 data, 1 stop, no parity Bi-Directional |
| Data Input | 1) 20 Key Keypad, 2) PS2 101 Keyboard (connector available at back of instrument) |
| Flow-through | < 0.5 % at 1 absorbance, 340/630 nm |
| Stability | Better than 0.003 A/hr monochromatic after warm-up Better than 0.001 A/hr bichromatic after warm-up |
| Warm-up Time | 90 seconds photometric 15 minutes for temperature compartment |
| Electronics | Z180 Microprocessor 18 MHz 128k EEPROM 32 K bytes Nonvolatile RAM (NVRAM) |
| Power | Auto-Switching Power Supply Voltage source: 90 – 264 VAC Frequency: 50/60 Hz Power consumption: 60 watts Installation Category: CAT II Fuses: 2.5A/250V Fast 5-20 mm Glass Fuse, 2.0A/250V Fast 5-20 mm Ceramic Fuse, (2) 6/10 250V Slow Blow 3AG Fuses |
| Dimensions and Weight | 40cm (L) x 37 cm (W) x 14 cm (H) lid closed (30 cm lid opened), 6.4 kg |