Siemens Immulite 2000 XPI Immunoassay System

Siemens Immulite 2000 XPI Immunoassay System
Contact us for price
or
Call 951.296.1266
Description
IMMULITE 2000 XPi Immunoassay System
The highly reliable IMMULITE® 2000 XPi system is easy to use and has one of the largest automated immunoassay menus available. Medium- to high-volume laboratories can incorporate specialty and allergy testing into routine workloads to improve productivity and efficiency.
Test Menu
Allergy | Anemia | Cardiac | Diabetes |
Allergen-Specific IgE 3gAllergy | Ferritin | High-sensitivity CRP | C-Peptide |
IgE, Total | Folate | Myoglobin | Insulin |
RBC Folate | Troponin I | Microalbumin | |
Autoimmune | Vitamin B12 | ||
Anti-CCP | |||
Bone Metabolism | Growth | Hepatitis | Metabolic |
Pyrilinks-D | Growth Hormone (hGH) | Anti-HBs | ACTH |
IGF-I | Anti-HBc IgM | Cortisol | |
IGFBP-3 | Anti-HBc Total | Homocysteine | |
Anti-HBs Quantitative | |||
Oncology | Reproductive Endocrinology | HBsAg | Other |
AFP | Androstenedione | HBsAg Confirmatory | ß-2 Microglobulin |
CA 125 (OM-MA) | DHEAS | Gastrin | |
CA 15-3 (BR-MA) | Estradiol | ||
Calcitonin | FSH | Veterinary2 | Special ID |
CEA | hCG | Canine TLI | H. pylori IgG |
Free PSA | LH | Canine Total T4 | Syphilis |
PAP | Progesterone | Canine TSH | |
PSA | Prolactin | Canine FT4 | |
SHBG | |||
Testosterone | |||
Unconjugated Estriol | |||
Therapeutic Drug Monitoring | Thyroid | ToRCH | |
Carbamazepine | Anti-TG | CMV IgG | |
Digitoxin | Anti-TPO | CMV IgM | |
Digoxin | Free T3 | Herpes I & II IgG | |
Phenobarbital | Free T4 | Rubella IgG | |
Phenytoin | Intact PTH | Rubella IgM | |
Theophylline | T Uptake | Toxoplasma IgG | |
Valproic Acid | TBG | Toxoplasma IgM | |
Thyroglobulin | |||
Total T3 | |||
Total T4 | |||
TSH | |||
TSH 3rd Generation | |||
TSI | |||
Specifications
Manufacturer | Siemens |
Condition | New |
System Description | Random access immunoassay system |
Throughput | Up to 200 tests per hour in batch or random access mode |
Time To First Result | 35 minutes |
Assays On Board | 24 |
Sample Tubes | 12-16 mm diameter 75-100 mm heights 10 x 50 microtubes with tube-top racks |
Sample Carriers | 15 position sample racks; 90 samples fully loaded; Continuous loading |
Walk Away Time | Up to 5 hours |
Sample Types | Serum, plasma, urine – assay dependent |
Sample Integrity Control | Pressure-transducer technology with clot detection, clot flagging, and short sample detection |
Automatic Sample Processing | Reflex, re-run, and dilutions |
Formats Supported | Code 39, Code 128, Codabar, UPC,and I-2 of 5 (Interleaved) |
Reagent Positions | 24 |
Reagent Cooling | 2 – 8° C |
Reagent Preparation | None required |
Reagent On Board Sability | 90 days |
Reagent Barcodes | Allows system to identify lot number, and determine when calibrator adjustment needed, and the tests remaining in the reagent wedge |
Operating System | Microsoft® Windows® 7 |
Monitor | 19 inch touch sensitive screen |
Daily | Automated daily maintenance cycle completed according to time programmed by the laboratory |
Weekly | 20 minutes |
Monthly | 45 minutes |
Operating Temperature | 18 – 32° C |
Height | 65 in / 165 cm |
Width | 93 in / 236cm |
Depth | 45 in / 114 cm |
Weight | 800 lbs / 363 kg |