Siemens ADVIA Centaur CP Immunoassay System

Siemens ADVIA Centaur CP Immunoassay System
Contact us for price
Description
The ADVIA Centaur CP System is an immunoassay test instrument for mid-volume labs. Its broad menu lets you both expand and consolidate – by bringing a wide range of assays to one workstation, eliminating redundant systems. The ADVIA Centaur CP System is easy to operate, increases efficiency and streamlines workflow. It offers the excellent sensitivity and specificity expected from direct Chemiluminescent with Acridinium Ester technology. The ADVIA Centaur CP Immunoassay System is a mid-volume, high-throughput bench top system that enhances your in-house test capability. With its broad menu and short Turn Around Times (TAT), you can do more — without compromising efficiency, productivity, or quality. And it features the superior sensitivity and specificity you expect of Chemiluminescent with Advanced Acridinium Ester Technology.
Test Menu
Reproductive Endocrinology
AFP
Anti-Müllerian Hormone*
DHEAS
Enhanced Estradiol
Free βhCG‡‡
FSH
hCG
LH
PAPP-A‡‡
PIGF*
Progesterone
Prolactin
SHBG
sFLT-1*
Testosterone II
Therapeutic Drug Monitoring
Carbamazepine
Digitoxin
Digoxin
Gentamicin
Phenobarbital
Phenytoin
Theophylline
Tobramycin
Valproic Acid
Vancomycin
Immunosuppressant Drugs
Cyclosporine
Everolimus*
Sirolimus*
Oncology
AFP
CA 125II‡
CA 15-3
CA 19-9
Calcitonin*
CEA
Complexed PSA
PSA
Serum HER-2/neu
Inflammation
IgE, Total
LBP*
IL-6*
Thyroid
Anti-Tg
Anti-TPO
Free T3
Free T4
T Uptake
Total T3
Total T4
TSH3-Ultra
TSH
ToRCH
CMV IgG
CMV IgM*
Herpes-1 IgG
Herpes-2 IgG
Rubella IgG
Rubella IgM
Toxoplasma IgG
Toxoplasma IgM*
Hepatitis
Anti-HBs-2
HAV IgM
HAV Total
HBc IgM
HBc Total
HBsAg Confirmatory
HCV**
Cardiac
BNP
CKMB
High-Sensitivity Troponin I
Myoglobin
Tnl-Ultra
Vitamin B12
Anemia
Active B12
EPO*
Ferritin
Folate
RBC Folate
Special ID
EBV-EBNA IgG*
EBV-VCA IgG*
EBV-VCA IgM*
Syphilis
Metabolic
Cortisol
Homocysteine
Diabetes
C-Peptide
Insulin
Bone Metabolism
Intact PTH
Autoimmune
Anti-CCP
Specifications
| Manufacturer | Siemens |
| Condition | New |
| Stock Number | 277 |
| System Description | Random access immunoassay system |
| Throughput | Up to 180 tests per hour in batch or random access mode |
| Time To First Result | 15 minutes |
| 15 minutes | 15 |
| Total Assay Capability | 100 |
| Sample Tubes | 5 mL, 7 mL, 10 mL, 1mL cups, microtainer tubes |
| Sample Capacity | 84 samples, continuous loading in 12-position sample racks |
| Walk Away Tme | One hour minimum |
| STAT Handling | Dedicated STAT position plus additional keyboard option for scheduling STATS individually |
| Sample Types | Serum, plasma, urine – assay dependent |
| Sample Integrity Control | Pressure based level sensing, short sample detection and flagging, clot detection and flagging, foamy sample detection |
| Sample Carryover | Eliminated by consumable ADVIA Centaur pipette tips |
| Sample Tips | ADVIA Centaur type, 480 on board, automatic tracking and flagging of inventory |
| Formats Supported | Code 128, Code 39, Codabar, Interleaved 2 of 5 (any or all symbologies may be active at one time) |
| Reagent Cooling | 10°C +-2 |
| Reagent Integrity Control | Barcode reagent identification, automatic inventory tracking and flagging, calibration validity tracked and flagged, reagent on board residency tracked and flagged, reagent expired/low flags |
| Ancillary Reagents | 10-position cooled storage for ADVIA Centaur reagent ancillaries |
| Type | ADVIA Centaur cuvettes |
| On Board Capacity | 400 |
| Loading/unloading of samples and consumables do not cause system interruption | Includes: Sample racks, STATS, reagent packs, ancillary reagents pack, reaction cuvettes, sample pipette tips, calibrators, controls, wash fluid, water |
| Operating System | Microsoft® Windows® XP English Professional |
| Monitor | 15″ diagonal LCD touch sensitive screen |
| Viewing and Editing | Results available at all times, sortable by SID test and date, user has the option to evaluate, verify and release results prior to printing or reporting to LIS. User edited results are flagged on audit trail |
| Identification | Barcode labels containing lot specific data, human readable and system readable through hand held barcode scanner |
| Status | Calibration Status logged and flagged, including advance notice of pending expiration, user-defined processes for response to calibration expiration |
| Package | Advanced QC package for long term monitoring including L-J plots and Westgard rules |
| Levels | 0-9 control levels per assay |
| Control Definitions | User defined |
| Results Storage | 25,000 control, patient and event results can be stored on line |
| Operating Temperature | 18-30°C |
| Operating Humidity | 20%-85% RH non condensing |
| Electrical | 100-240v, 50/60Hz |
| Dimensions | Height: 32 in/81 cm Width: 43 in/107 cm Depth: 29 in/74 cm (excludes monitor and accessories) |
| Weight | 366lbs/166kg (includes monitor and accessories) |