Roche Cobas E411 Fully Automated Immunoassay Analyzer

Roche Cobas E411 Fully Automated Immunoassay Analyzer

Contact us for price

Description

Roche Cobas E411 Immunoassay Analyzer

Includes:

One cobas E411 analyzer with computer, software, bench, and manual.


The cobas e 411 analyzer is a fully automated analyzer that uses a patented ElectroChemiLuminescence (ECL) technology for immunoassay analysis. It is designed for both quantitative and qualitative in vitro assay determinations for a broad range of applications, including:

  • Anemia
  • Bone, cardiac, and tumor markers
  • Critical care
  • Fertility/hormones
  • Infectious diseases

The analyzer is available with either a rack or disk sample handling system.


Features/Benefits:

  • High sensitivity, reliability, and reproducibility of results due to ECL technology
  • More than 100 assays available¹
  • Up to 18 assays can be run at a throughput of up to 86 tests/hour²
  • 9 min STAT applications for emergency sample assays, including:
  • TnT Gen. 5
  • Creatine-Kinase MB
  • Myoglobin
  • Parathyroid Hormone (PTH)
  • Human Chorionic Gonadotropin (hCG)¹


Test Menu

Elecsys® ACTH

Elecsys® Anti-TPO

Elecsys® Cyclosporine

Elecsys HBeAg

Elecsys® AFP

Elecsys® Anti-TSHR

Elecsys® CYFRA 21-1

Elecsy HBsAg Confirmatory Test

Elecsys® AMH

Elecsys® C-Peptide

Elecsys® DHEA-S

Elecsys HBsAg II

Elecsys® Anti-CCP

Elecsys® CA 125 II

Elecsys® Digoxin

Elecsys CG STAT

Elecsys® Anti-HAV

Elecsys® CA 15-3 II

Elecsys® Estradiol III

Elecsys CG+

Elecsys® Anti-HAV IgM

Elecsys® CA 19-9

Elecsys® Ferritin

Elecsys HE4

Elecsys® Anti-HBc IgM

Elecsys® Calcitonin

Elecsys® Folate III

Elecsys hGH

Elecsys® Anti-HBc II

Elecsys® CEA

Elecsys® Folate RBC

Elecsys HSV-1 IgG

Elecsys® Anti-HBe

Elecsys® CK-MB

Elecsys® free PSA

Elecsys HSV-2 IgG

Elecsys® Anti-HCV II

Elecsys® CMV IgG

Elecsys® free βhCG

Elecsys IgE II

Elecsys® Anti-SARS-CoV-2 S

Elecsys® CMV IgM

Elecsys® FSH

Elecsys IGF-1

Elecsys® Anti-Tg

Elecsys® Cortisol II

Elecsys® FT3 III

Elecsys IGFBP-3

Elecsys® IL-6

Elecsys Prolactin II

Elecsys® Tacrolimus

Elecsys® Insulin

Elecsys PTH

Elecsys® Testosterone II

Elecsys® LH

Elecsys Rubella IgG

Elecsys® total PSA

Elecsys® Myoglobin

Elecsys Rubella IgM

Elecsys® Total-Tau CSF

Elecsys® N-MID Osteocalcin

Elecsys S100

Elecsys® Toxo IgG

Elecsys® NSE

Elecsys SARS-CoV-2 Antigen

Elecsys® Toxo IgM

Elecsys® PAPP-A

Elecsys sFlt-1

Elecsys® Troponin I

Elecsys® Phospho-Tau (181P) CSF

Elecsys SHBG

Elecsys® TSH

Elecsys® PlGF

Elecsys Syphilis

Elecsys® Vitamin B12 II

Elecsys® proBNP II

Elecsys T-Uptake

Elecsys® Vitamin D total II

Elecsys® Progesterone III

Elecsys T3

Elecsys® β-CrossLaps/serum

Elecsys® ProGRP

Elecsys T4

Specifications

ManufacturerRoche Diagnostics
ConditionNew
Stock Number281
WeightDisk: 180 kg / 397 lbs  Rack: 250 kg / 551 lbs
SystemFully automated, immunoassay analyzer for random access processing of ECL-based immunoassays (cobas e system format)
System componentsSelf contained bench top analyzer comprising an analytical unit and a customized user interface
Types of modulescobas e 411 disk analyzer  cobas e 411 rack analyzer Optional System Table (cabinet); Optional System Table Extension (for printer)
System interfacesRS232 serial interface, bidirectional
ThroughputUp to 86 tests/hour
Number of reagent channels25 reagent slots with a maximum of 18 on-board assays
Programmable test parametersN/A, programming-by-loading (PBT) concept, application data are transferred without operator intervention from the 2D barcode of the reagent pack (RP) into the instrument database
Sample materialsSerum/plasma, urine, others
Sample input/output30 positions for samples, calibrators and controls  15 racks with 5 samples each (= 75 samples in/out)
Sample volume10 – 50 μl.
Sample clot detectionStandard (pressure sensor)
Sample barcode typesCode 128; Codabar (NW 7); Interleaved 2 of 5; Code 39
Control unitMicrosoft® Windows® XP-based panel PC
Calibrator/QC inputcobas e system-specific barcoded CalSet vials on disk or racks
Calibration methodsLot calibration (L-cal); Reagent Pack (RP) calibration (R-Cal)
QC methodsIndividual QC and cumulative QC  Up to 100 controls pre-programmable
Data storage capacityThe memory contains data files necessary for the analyzer and software to work together:  Reagent Data File: Up to 300 reagent packs  Sample Data File: Up to 2000 test records (for samples and controls)  Calibration Data File: Up to 160 calibrators – QC Data File: Capacity up to 100 controls  Operating Parameter Data File: Up to 305 reagent applications  Up to 20 operator IDs
Electrical requirements230/110 Volts AC; 1,000 kVA (disk), 1,250 kVA (rack)  Frequency: 50 Hz or 60 Hz +/- 0.5%
Water/Waste requirementsWater: Bacteria free, de-ionized water supply, resistance of less than 10 μS/cm  Liquid waste: Onboard waste container (4 liter), direct drain optional
Operating conditionsAmbient temperature: 18 to 32°C  Ambient humidity: 20 to 80% RH (without condensation)  Heat Output: 2,879 kJ/hr (analyzer unit)  Noise Output: 60 dBA (stand-by), 63 dBA (operation avg.)
Physical dimensionsWidth (disk/rack): 120 cm / 170 cm 47.2 in / 67 in  Depth (disk/rack): 73 cm / 95 cm 28.7 in / 37.4 in  Height: 80 cm / 31.4 in (closed top cover) 109 cm / 43 in (opened top cover)