Roche Cobas E411 Fully Automated Immunoassay Analyzer

Roche Cobas E411 Fully Automated Immunoassay Analyzer

Contact us for price

Description

Roche Cobas E411 Immunoassay Analyzer

Overview:

The cobas e 411 analyzer is a fully automated analyzer that uses a patented ElectroChemiLuminescence (ECL) technology for immunoassay analysis. It is designed for both quantitative and qualitative in vitro assay determinations for a broad range of applications

Includes:

·         Analyzer with computer

·         Software

·         Bench

·         Manual

Features:

  • High sensitivity, reliability, and reproducibility of results due to ECL technology
  • More than 100 assays available¹
  • Up to 18 assays can be run at a throughput of up to 86 tests/hour²
  • 9 min STAT applications for emergency sample assays, including:
  • TnT Gen. 5
  • Creatine-Kinase MB
  • Myoglobin
  • Parathyroid Hormone (PTH)
  • Human Chorionic Gonadotropin (hCG)¹

 

Specifications:

System Overview

·         Fully automated, random-access immunoassay analysis system

·         Available in two configurations:

·         Disk system

·         Rack system

System Components

·         Analytical Module

o   Windows XP Embedded operating system

o   Integrated touch-screen PC

Sample Handling Module

·         Rack-operated or disk-operated configuration

Performance

·         Sample Throughput: Up to 88 samples/hour (theoretical maximum)

·         Test Throughput: Up to 88 tests/hour (theoretical maximum)

·         Number of Channels: 18 reagent channels/slots

o   Supports up to 18 different assays simultaneously

·         Programmable Assays: Up to 60 assays

o   Assay parameters programmable via 2D barcode

o   Programming by loading reagent/assay information

Sample Types

·         Serum

·         Plasma

·         Urine

Sample Input / Output Capacity

·         Disk System: Up to 30 samples

·         Rack System: Up to 75 samples on 15 racks

·         Rack: RD standard 5-position rack

·         Rack Types:

o   Routine

o   STAT

o   Control

o   Calibrator

STAT Sample Handling

·         Any unoccupied position on the sample disk

·         Dedicated STAT port on the rack feeder

Sample Containers

·         Primary Tubes: 5–10 mL

o   16 × 100 mm

o   16 × 75 mm

o   13 × 100 mm

o   13 × 75 mm

·         Sample Cups: 2.5 mL

·         Micro Cups: Not supported

·         Cup-on-Tube: Cup can be placed on top of a 16 × 75 mm or 16 × 100 mm tube

·         Sample Volume

o   Sample Volume per Test: 10–50 µL, depending on assay protocol

Minimum Sample Volume

·         Primary Tubes:

o   13 mm tube: 600 µL

o   16 mm tube: 1,000 µL

·         Sample Cup:

o   Standard cup-on-tube: 200 µL

o   Special setting: 150 µL

Sample Barcode Types

·         Code 128

·         Codabar (NW 7)

·         Interleaved 2 of 5

·         Code 39

On-Board Control Unit

·         PC with Pentium III processor

·         Color 15-inch SVGA touch-screen monitor

·         Windows XP Embedded operating system

System Interfaces

·         RS-232 serial interface

·         Bi-directional communication

·         Standard PC connectivity, including:

o   USB

o   Ethernet

o   Serial ports

o   Other communication interfaces for peripheral devices

Sample Database

  • Capacity: Up to 2,000 test results
  • Stores results for:
  • Routine testing
  • STAT testing
  • Control testing

Test Methods

  • Pre-defined assay protocols, including:
  • Sandwich
  • Competitive
  • Titration

Calibrator & Quality Control (QC)

  • Calibrator/QC Input:
  • Rack system
  • Sample disk
  • Calibration:
  • Calibration triggered upon QC failure
  • 2-point calibration
  • Calibration performed per lot or per cobas e-pack
  • QC Methods:
  • Individual QC
  • Cumulative QC
  • Preventive QC after calibration

Electrical Requirements

  • Power Requirements:
  • 100–120 VAC, 50/60 Hz, single phase
  • 200–240 VAC, 50/60 Hz, single phase
  • Power Consumption: 800 VA

Water & Waste Requirements

  • Water Container Capacity: 3 liters
  • Water Quality Requirements:
  • 10 µS/cm or 0.1 MΩ
  • Bacteria-free water
  • Water Consumption:
  • Approximately 3 L per 250 tests
  • Approximately 12 mL per cycle

Regulatory Certifications

  • GS
  • CE
  • UL
  • C-UL
  • CB Report and Certificate

Operating Conditions

  • Ambient Temperature: 18–32 °C (64.4–89.6 °F)
  • Ambient Humidity: 20–80%

Noise Level

  • Standby Mode: 60 dBA
  • Average During Operation: 63 dBA

Physical Specifications

  • Width: 1,200–1,700 mm (disk/rack configuration)
  • Depth: 730–950 mm (disk/rack configuration)
  • Height: 560 mm (without PC unit)
  • Weight:
  • Disk configuration: Approximately 170 kg
  • Rack configuration: Approximately 210 kg

 Assay Menu:

Thyroid Function:

·         Anti-Tg

·         Anti-TPO

·         Anti-TSH-receptor

·         FT3

·         FT4

·         T3

·         T4 T-Uptake

·         Tg

·         TSH

·         Fertility / Hormones:

·         ACTH

·         C-peptide

·         Cortisol

·         DHEA-S

·         Estradiol

·         free B-HCG

·         FSH

·         HCG+B

·         HCG STAT

·         Insulin

·         LH

·         PAPP-A

·         Progesterone

·         Prolactin

·         SHBG Testosterone

 Anemia:

·         Ferritin

·         Vitamin B12

·         Folate

·         RBC Folate

Tumor Markers:

·         AFP

·         CA 125 II

·         CA 15-3

·         CA 19-9

·         CA 72-4

·         CEA

·         CYFRA 21-1

·         free PSA

·         NSE

·         S-100

·         total PSA

Cardiac:

·         CK-MB (mass)

·         CK-MB (mass) STAT

·         Digoxin

·         Digitoxin

·         Myoglobin

·         Myoglobin STAT

·         NT-proBNP

·         Troponin T

·         Troponin T STAT

·         Troponin I*

·         Troponin T HS*

 Maternal Care:

·         AFP

·         free β HCG

·         hCG+ β

·         PAPP-A

·         PLGF

·         sFLt

Critical Care:

·         IL6

·         PCT

·         S-100

Infectious Disease:

·         Anti-HAV

·         Anti-HAV IgM

·         Anti-HBc

·         Anti-HBc IgM

·         Anti-Hbe

·         Anti-HBs

·         Anti-HCV

·         HBsAg confirmatory

·         CMV IgG

·         CMV IgM

·         HBeAg

·         HBsAg

·         HIV Antigen

·         HIV Antigen confirmatory

·         HIV combi

·         Rubella IgG

·         Rubella IgM

·         Toxo IgG

·         Toxo IgM

Bone Markets:

·         B-CrossLaps

·         25-(OH)2 Vitamin D3

·         Intact PTH

·         N-MID Osteocalcin

·         PTH STAT

·         Total-P1NP

 Other:

·         IgE

·         S-100 (brain damage)

·         Anti-CCP

 

International Diagnostic Equipment 

- Call or email with your questions , Hablamos Español

- Ship from: IDE - Southern California. Global Shipping

- Details of item must be read carefully before buying and /or requesting return

 

Disclaimer:


"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item."

 

 

 

 

 


Specifications

ManufacturerRoche Diagnostics
ModelE411
ConditionRefurbished
Stock Number281
WeightDisk: 180 kg / 397 lbs  Rack: 250 kg / 551 lbs
SystemFully automated, immunoassay analyzer for random access processing of ECL-based immunoassays (cobas e system format)
System componentsSelf contained bench top analyzer comprising an analytical unit and a customized user interface
Types of modulescobas e 411 disk analyzer  cobas e 411 rack analyzer Optional System Table (cabinet); Optional System Table Extension (for printer)
System interfacesRS232 serial interface, bidirectional
ThroughputUp to 86 tests/hour
Number of reagent channels25 reagent slots with a maximum of 18 on-board assays
Programmable test parametersN/A, programming-by-loading (PBT) concept, application data are transferred without operator intervention from the 2D barcode of the reagent pack (RP) into the instrument database
Sample materialsSerum/plasma, urine, others
Sample input/output30 positions for samples, calibrators and controls  15 racks with 5 samples each (= 75 samples in/out)
Sample volume10 – 50 μl.
Sample clot detectionStandard (pressure sensor)
Sample barcode typesCode 128; Codabar (NW 7); Interleaved 2 of 5; Code 39
Control unitMicrosoft® Windows® XP-based panel PC
Calibrator/QC inputcobas e system-specific barcoded CalSet vials on disk or racks
Calibration methodsLot calibration (L-cal); Reagent Pack (RP) calibration (R-Cal)
QC methodsIndividual QC and cumulative QC  Up to 100 controls pre-programmable
Data storage capacityThe memory contains data files necessary for the analyzer and software to work together:  Reagent Data File: Up to 300 reagent packs  Sample Data File: Up to 2000 test records (for samples and controls)  Calibration Data File: Up to 160 calibrators – QC Data File: Capacity up to 100 controls  Operating Parameter Data File: Up to 305 reagent applications  Up to 20 operator IDs
Electrical requirements230/110 Volts AC; 1,000 kVA (disk), 1,250 kVA (rack)  Frequency: 50 Hz or 60 Hz +/- 0.5%
Water/Waste requirementsWater: Bacteria free, de-ionized water supply, resistance of less than 10 μS/cm  Liquid waste: Onboard waste container (4 liter), direct drain optional
Operating conditionsAmbient temperature: 18 to 32°C  Ambient humidity: 20 to 80% RH (without condensation)  Heat Output: 2,879 kJ/hr (analyzer unit)  Noise Output: 60 dBA (stand-by), 63 dBA (operation avg.)
Physical dimensionsWidth (disk/rack): 120 cm / 170 cm 47.2 in / 67 in  Depth (disk/rack): 73 cm / 95 cm 28.7 in / 37.4 in  Height: 80 cm / 31.4 in (closed top cover) 109 cm / 43 in (opened top cover)