Roche Cobas 6000 (c501 + e601) Chemistry Analyzer

Roche Cobas 6000 (c501 + e601) Chemistry Analyzer

Contact us for price

Description

The Cobas 6000 analyzer series offers tailor-made solutions for medium to large workload laboratories. Flexible combinations of clinical chemistry (Cobas C501 module) and immunochemistry testing (Cobas E601 module) modules are available.



Core Unit

  • Simple operation with continuous loading and unloading
  • Loading capacity of 150 samples in two trays of 75
  • Load 5-position racks via dedicated STAT port with rerun buffer or by tray
  • Unique 5-position rack for more efficient sample handling
  • Smart track rotor for intelligent sample handling
  • Single control unit for all modules

Cobas C501 Module

  • Clinical chemistry, homogeneous immunoassays, ISE, HbA1c (whole blood measurement)
  • Throughput of up to 1,000 tests/hour
  • 60 reagent channels plus 3 ISEs
  • Reagent loading on the fly
  • Specimen integrity via serum indices (parallel processing), clot and liquid level detection
  • Contact-free ultrasonic mixing
  • Automated rerun and dilution

Cobas E601 Module

  • Heterogeneous immunoassays including cardiac markers, anemia, bone and tumor markers, hormones, and infectious diseases
  • Electrochemiluminescence (ECL) technology
  • Throughput up to 170 tests/hour
  • 25 reagent channels
  • Carry-over free disposable tips and cups
  • 9-minute STAT applications for Troponin I and T, proBNP II, Myoglobin, hCG, and CKMB
  • Clot and liquid level detection
  • Automated rerun and dilution

Escape from Corporate Service Contracts in California

The quality of service contracts from manufacturers has declined over the last 10 years. They are less responsive, slower, and more corporatized. With IDE:

  • Your service engineer is local in California
  • Call or text your service engineer directly
  • Same day phone service, next-day on-site service in California, next-flight service anywhere in the US
  • Faster repairs because parts are kept in stock

Increase Throughput, Uptime, and Value of Every Test

  • Your refurbished Roche Cobas 6000 is returned to like-new specs
  • Tens of thousands of dollars less than new systems
  • Investment pays for itself within 2 years through efficiency and reduced downtime
  • Financing options available
  • Extend the lifespan of your primary analyzers by 5+ years

Make Onboarding New Staff Easier in California

  • Refurbished systems reduce training time for inexperienced staff
  • Error rates drastically reduced
  • Oversight time reduced in the first 9 months
  • Easy adoption because many candidates are already familiar with Cobas systems

Get Personal, Responsive Service in California

  • Direct access to your service engineer
  • Family-style business approach
  • Guidance provided until system is fully operational
  • Avoid frustration with large, centralized service providers

All-in-One Support for Your Roche Cobas System

  • Parts, reagents, and preventive maintenance in one place
  • Avoid cobbling together multiple suppliers
  • Trade-in options for old analyzers to save on upgrades
  • Maintain low environmental impact

Service Options in California

  • Preventive maintenance to reduce downtime
  • Tailored service agreements
  • Same-day phone support
  • Affordable depot service for repairs or refurbishment
  • Decontamination and relocation assistance
  • Installation, IQ/OQ validation, calibration, quality control, and professional training

COBAS C501 Module

6AM

A1C-3

A1MG2

A2MG

AAGP2

AAT2

ACET2

ALB2

ALBP

ALP2

ALT

ALTL

ALTLP

AMIK2

AMPS2

AMY-P

AMYL2

APOAT

APOBT

ASLOT

ASTL

ASTLP

B2MG

BARB

BENZ

BILT3

BUP

C3C-2

C4-2

CA2

CARB4

CERU

CHE

CHE2

CHOL2

CK

CO2-L

COC2

CREJ2

CREP2

CRP4

CRPHS

CRPLX

CYSC2

D Bili

D-DI

DIG

EDDP

ETOH2

FEN2

FERR4

FRA

GENTC

GGT-2

GLUC2

GLUC3

HAPT2

HCYS

HYD

IGA-2

IGG-2

IGM-2

LACT2

LDHI2

LDLC3

LFLC

LI

LPA2

LSD

MDN2

Methadone Metabolite

MG2

MPA

MTQL

MYO2

NAPA2

NH3L

NH3L2

OPI2

OXY

PCP

PHNO2

PHNY2

PPX

PREA

PROC2

QUIN2

RF-II

SALI

SI2

STFR

SVTCH

SVTCR

SVTNI

SVTOX

SVTpH

SVTSG

THC2

THEO2

TOBR2

TP2

TPUC3

TRIGL

UA2

UIBC

UREAL

VALP2

VANC3

β2-Microglobulin


COBAS E601 Module

Elecsys ACTH

Elecsys AFP

Elecsys AMH

Elecsys Anti-CCP

Elecsys Anti-HAV

Elecsys Anti-HAV IgM

Elecsys Anti-HBc IgM

Elecsys Anti-HBc II

Elecsys Anti-HBe

Elecsys Anti-HCV II

Elecsys Anti-SARS-CoV-2 S

Elecsys Anti-Tg

Elecsys Anti-TPO

Elecsys Anti-TSHR

Elecsys BRAHMS PCT

Elecsys C-Peptide

Elecsys CA 125 II

Elecsys CA 15-3 II

Elecsys CA 19-9

Elecsys Calcitonin

Elecsys CEA

Elecsys CK-MB

Elecsys CMV IgG

Elecsys CMV IgM

Elecsys Cortisol II

Elecsys Cyclosporine

Elecsys CYFRA 21-1

Elecsys DHEA-S

Elecsys Digoxin

Elecsys Estradiol III

Elecsys Ferritin

Elecsys Folate III

Elecsys Folate RBC

Elecsys free PSA

Elecsys free βhCG

Elecsys FSH

Elecsys FT3 III

Elecsys HBeAg

Elecsys HBsAg Confirmatory Test

Elecsys HBsAg II

Elecsys HCG STAT

Elecsys HCG+β

Elecsys HE4

Elecsys hGH

Elecsys HSV-1 IgG

Elecsys HSV-2 IgG

Elecsys IgE II

Elecsys IGF-1

Elecsys IGFBP-3

Elecsys Insulin

Elecsys LH

Elecsys Myoglobin

Elecsys NSE

Elecsys N-MID Osteocalcin

Elecsys PAPP-A

Elecsys Phospho-Tau (181P) CSF

Elecsys PlGF

Elecsys proBNP II

Elecsys Progesterone III

Elecsys ProGRP

Elecsys Prolactin II

Elecsys PTH

Elecsys Rubella IgG

Elecsys Rubella IgM

Elecsys S100

Elecsys SARS-CoV-2 Antigen

Elecsys sFlt-1

Elecsys SHBG

Elecsys Syphilis

Elecsys T-Uptake

Elecsys T3

Elecsys T4

Elecsys Tacrolimus

Elecsys Testosterone II

Elecsys Total-Tau CSF

Specifications

ManufacturerRoche Diagnostics
ConditionNew
Stock Number283
System2nd Generation SWA: modular, analytical system platform, consolidated work area for Clinical Chemistry and Immunology, expandable and re-configurable on site
Types of modules· cobas c 501 module: Photometric measuring unit (incl. ISE) · cobas e 601 module: Electrochemiluminescence (ECL) technology measuring unit
Number of configurations7 module combinations; Up to 3 modules in one core unit · cobas c 501 modules: 1 to 2 modules · cobas e 601 modules: 1 to 2 modules · cobas c 501 | cobas e 601 modules: 2 to 3 modules (only 2 units of 1 module type for SWA combinations possbile)
Sample throughputUp to 120 racks/hour or 600 samples/hour
Test throughput  (theoretical max)· 170 up to 2,170 tests/hour: overall · 1,000 up to 2,000 tests/hour:with cobas c 501 modules · 170 up to 340 tests/hour:with cobas e 601 modules · 1,170 up to 2,170 tests/hour: with cobas c 501 and cobas e 601 modules
Number of reagent channels  (reagent slots)Up to 151 channels, in total 63 channels (including ISE, automatic setting) on cobas c 501 module 25 channels on cobas e 601 module
Sample materialSerum, Plasma, Urine, CSF
Core unit analytics· Rack: 5 position rack, RD standard rack · Rack types: Routine, STAT, Control, Calibrator, Rerun (manual), Wash · Tray: Tray with 15 racks/75 samples, RD standard tray · STAT port: STAT samples are processed with true STAT interrupt
Sample container types· Primary tubes: 5 to 10 mL; 16 x 100, 16 x 75, 13 x 100, 13 x 75 mm · Sample cup: 2.5 mL · Micro cup: 1.5 mL, (exception: cobas e 601 module) · Cups on tube: Cup on top of a 16 x 75/100 mm tube; Cup on top of one non standard tube · False bottom tube (FBT): One type is definable
Sample volume1–35 µL
Sample dilution3–121 times
Sample clot detectionAvailable for cobas c 501 and cobas e 601 module
Minimum sample volume· Primary tubes: 700 µL · Sample cup: 100 µL · Micro cup (FTB): 50 µL
Sample barcode typesCode 128; Codabar (NW 7); Interleaved 2 of 5; Code 39
System interfacesRS 232 serial interface, bi-directional Interface to cobas link data station for cobas teleservice functionalities and automatic download
Sample data base10.000 routine/STAT samples
Test methodsFor photometric modules: 1 point, 1 point + prozone check, 2 point, 2 point kinetic, 2 point + prozone check, 3 point, 1 point + kinetics Rate A, Rate A + serum index, Rate A with blank, Rate B
Calibrator/QC inputVia specified racks through the input buffer or STAT port
Calibration methodsStart-up, Re-calibration For photometric modules: Linear, non-linear multi-points, 2 point calibration, K-factor up to 100 different calibrators pre-programmable Storage of up to 180 curves Preventive calibration of the stand-by cobas c and cobas e packs on cobas c 501: Two k-factor can be defined for different sample types
QC methodsFor e- and photometric modules: Real-time QC, individual QC, cumulative QC Up to 100 controls pre-programmable Preventive QC after calibration of the stand-by cassettes/rack packs Auto QC: QC without operator intervention (timer triggered)
Rerun/reflex functionAutomatic rerun and manual rerun; Automatic reflex is supported by the system, reflex request to be provided by Roche Middleware Solutions
Electrical requirements· Power requirements: 230 Volts AC; 110 Volts AC 2.4 kVA (for cobas c 501 | e 601) · Frequency: 50 Hz or 60 Hz +/- 0.5%
Water/waste requirements· Water: Bacteria free, deionised water supply: resistance of < 1,0 µS/cm · Water pressure: 0.5 – 3.5 kg/cm3, (49–343 Kpa) · Biohazards waste: Separate container behind the system · L. concentrated: Central drain port, diameter: = 50 mm / 2 inches · Waste drain < waste: 100 mm above the floor / 4 inches
Water consumption· Max flow rate: cobas c 501 module: approx. 40 L/hour · Typical consumption: cobas e 601 module: approx. 30 L/hour
Operational conditions· Ambient temperature: 15 to 32°C / 59 to 90°F · Ambient humidity: 30 to 85% (RH, without condensation) · Heat output: 1.5 kW (5400 kJ/hr for cobas c 501, 4320 kJ/hr for cobas e 601) · Noise output: < 65 dB
Physical dimensions· Width: 188 to 498 cm / 74 to 196 inches · Core unit: 69 cm / 27.2 inches cobas c or cobas e module: 120 cm / 47.2 inches · Depth: cobas c or cobas e module: 98 cm / 38.6 inches Core unit: 104 cm / 41 inches · Height: 130 cm / 51 inches · Control unit: Width: 80 cm / 31.5 inches, depth: 80 cm / 31.5 inches
Weight· cobas c 501 module: 330 kg / 730 lbs · cobas e 601 module: 360 kg / 795 lbs · Core unit (sample loader, control unit, rack rotor): 180 kg / 400 lbs