Mindray BS 480 Chemistry Analyzer. A floor-standing, discrete and random access clinical chemistry analyzer offering a constant 400 tests per hour. The BS-480 chemistry analyzer is a versatile mid to high volume chemistry platform with conventional software design, easy to navigate interface; creating a positive user experience in today’s fast-paced laboratory environment. The wide selection test menu includes general chemistries and electrolytes serving the need of most clinical laboratories and hospitals.


Specific Proteins

Immunoglobulin A (IgA)

Immunoglobulin G (IgG)

Immunoglobulin M (IgM)

Immunoglobulin E (IgE) *

Complement C3 (C3)

Complement C4 (C4)

C-Reactive Protein (CRP)

Lipoprotein(a) [LP(a)]

Prealbumin (PA)

High sensitivity C-reactive protein (hs-CRP)

Rheumatoid Factor (RF)

Antibodies Against Streptolysin O (ASO)

Homocysteine (HCY)

Ferritin (FER)

Transferrin (TRF)

Total iron binding capacity / unsaturated iron Binding capacity (TIBC/UIBC)

Myoglobin*

D-dimer*

Retinol binding protein (RBP) *

Fructosamine (FUN)

Hemoglobin A1c (HbA1c)

Cystatin C (CysC)

Microalbumin

β2-Microglobulin (β2-MG) *

Substrates

Total Cholesterol (TC)

Triglycerides (TG)

HDL-Cholesterol (HDL-C)

LDL-Cholesterol (LDL-C)

Apolipoprotein A1 (ApoA1)

Apolipoprotein B (ApoB)

Direct Bilirubin (D-Bil) DSA

Direct Bilirubin (D-Bil) VOX

Total Bilirubin (T-Bil) DSA

Total Bilirubin (T-Bil) VOX

Total Protein (TP)

Albumin (ALB)

Total Bile Acids (TBA)

Glucose (Glu) GOD-POD

Glucose (Glu) HK

Urea (UREA)

Creatinine (CREA) Modified Jaffé

Creatinine (CREA) Enzymatic

Uric Acid (UA)

Carbon dioxide (CO2)

Enzymes

Alanine Aminotransferase (ALT)

Aspartate Aminotransferase (AST)

Alkaline Phosphatase (ALP)

γ-Glutamyl Transferase (γ-GT)

α-Amylase (α-AMY)

Lactate Dehydrogenase (LDH)

Lipase (LIP)

Cholinesterase (CHE)

Adenosine deaminase (ADA)

α-L-fucosidase (AFU)

5′-nucleotidase (5′-NT)

Creatine Kinase (CK)

Creatine Kinase-MB (CK-MB)

α-Hydroxybutyrate Dehydrogenase (α-HBDH)

Glucose-6-phosphate dehydrogenase (G6PD) *

Angiotensin converting enzyme (ACE) *

D3-hydroxybutyric acid (D3-HB) *

Electrolytes/ISE

Chloride(Cl)

Potassium(K)

Sodium(Na)

Inorganic ions

Calcium (Ca)

Magnesium (Mg)

Phosphate Inorganic (P)

Iron (Fe)

The BS-480 Chemistry Analyzer is a fully automated, discrete, random access system designed for STAT, urine, and homogeneous immunoassays, with STAT sample priority. It supports single, dual, triple, and quadruple reagent chemistries and can operate in monochromatic or bichromatic modes. Sample handling is optimized with carry-over of less than 0.05%, and the analyzer provides automatic sample dilution, including pre-dilution and post-dilution. An internal barcode reader enables sample and reagent barcode reading, compatible with Codabar, ITF (Interleaved Two of Five), Code128, Code39, UPC/EAN, and Code93 formats. The system also supports bi-directional LIS interface transmission.

An optional ISE module allows measurement of potassium (K+), sodium (Na+), and chloride (Cl). Reagent handling includes automatic inventory checks to ensure uninterrupted operation. The reaction system can measure at wavelengths of 546 nm, 570 nm, 605 nm, 660 nm, 700 nm, 740 nm, and 800 nm. Control and calibration options include point calibration, Logit-Log 4P, Logit-Log 5P, Spline, exponential, Polynomial, and Parabola methods, with cumulative sum checks and twin plot functionality.

The operation unit is designed for standard laboratory working conditions, operating at 110–130V, 60Hz, and 1500VA.

Specifications

ManufacturerMindray
ConditionNew
Stock Number288
ThroughputUp to 240 tests per hour
Measuring principlesAbsorbance Photometry, Turbidimetry
MethodologyEnd-point, Fixed-time, Kinetic, ISE (Optional)
ProgrammingUser defined profiles and calculation
Sample tray90 positions for primary or secondary tubes and sample cups
Sample volume1.5~45 µl, step by 0.1µl
Sample probeLiquid level detection, clot detection and collision protection
Probe cleaningInterior and exterior automatic probe washing
Dilution with ratio up to 1150
Dilution vesselPermanent Cuvette
Reagent tray80 positions in refrigerated compartment (2~10°C)
Reagent volumeR1: 45- 350 ul, R2 ~ R4 :10 – 350ul
Reagent probeLiquid level detection, collision protection and
Reaction rotorRotating tray, 90 cuvettes with automatic washing
CuvetteOptical length 5mm
Reaction volume120~360µl
Operating temperature37°C
Temperature fluctuation±0.1°C
Mixing system2 independent mixers
Light SourceHalogen-tungsten lamp
PhotometerReversed optics, grating photometry
Wavelength340nm, 380nm, 412nm, 450nm, 505nm,
Absorbance range0~3.3Abs (10mm conversion)
Resolution0.0001Abs
Calibration modeLinear (one-point, two-point and multi
Control rulesWestgard multi-rule, Levy-Jennings,
Operation systemWindows 8
InterfaceRS-232, Network Port, USB/ parallel port
Power Supply200~240V, 50/60Hz, 1500VA
Temperature15~30°C
Humidity35~85%
Water consumption≤20L/hour, De-ionized water
Dimension46in x 28in x 45in (W x D x H)
Weight661lb